We developed and validated an assay for determination of glyphosate (GLYP) and glufosinate (GLUF) in human serum. Serum samples were extracted by using a MonoSpin® TiO column and analyzed by liquid chromatography–tandem mass spectrometry (LC–MS/MS). MonoSpin® TiO tends to specifically bind to phosphate groups. The assay was linear over a concentration range of 1–250 μg/mL. The recoveries for the 2 compounds were 1.6%–2.3%. The intra- and inter-day variations were <15%. Precision and accuracy were 5.6%–12.7% and 97.0%–103.9%, respectively. The validated method was applied to quantify the GLYP and GLUF content in the serum of GLYP and GLUF-poisoned patients. In conclusion, the method was successfully applied for accurate determination of GLYP and GLUF in serum obtained from patients with GLYP and GLUF poisoning.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
10--15
Opis fizyczny
Bibliogr. 19 poz., rys., tab.
Twórcy
autor
- Tokai University School of Medicine, Isehara, Kanagawa 259-1143, Japan
autor
- Hiroshima University, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8553, Japan
autor
- Tokai University School of Medicine, Isehara, Kanagawa 259-1143, Japan
autor
- Department of Emergency, Kagoshima City Hospital, Uearata, Kagoshima, Kagoshima 890 8760, Japan
autor
- Tokai University School of Medicine, Isehara, Kanagawa 259-1143, Japan
Bibliografia
- [1] Koyama, K.; Andou, Y.; Saruki, K.; Matsuo, H. Vet. Hum. Toxicol. 1994, 36, 17.
- [2] Watanabe, T.; Sano, T. Hum. Exp. Toxicol 1998, 17, 35.
- [3] Tanaka, J.; Yamashita, M.; Yamashita, M.; Matsuo, H.; Yamamoto, T. Vet. Hum. Toxicol 1998, 40, 219.
- [4] Hirose, Y.; Kobayashi, M.; Koyama, K.; Kohda, Y.; Tanaka, T.; Honda, H.; Hori, Y.; Yoshida, K.; Kikuchi, M. Hum. Exp. Toxicol 1999, 18, 305.
- [5] Matsukawa, Y.; Hachisuka, H.; Sawada, S.; Horie, T.; Kitammi, Y.; Nishijima, S. Clin. Toxicol 1991, 29, 141.
- [6] Ohtake, T. Hum. Exp. Toxicol 2001, 20, 429.
- [7] Motojyuku, M.; Saito, T.; Akieda, K.; Otsuka, H.; Yamamoto, I.; Inokuchi, S. J. Chromatogr. B 2008, 875, 509.
- [8] Saito, T.; Aoki, H.; Namera, A.; Oikawa, H.; Miyazaki, S.; Nakamoto, A.; Inokuchi, S. Anal. Sci 2011, 27, 999.
- [9] Saito, T.; Miura, N.; Namera, A.; Oikawa, H.; Miyazaki, S.; Nakamoto, A.; Inokuchi, S. Forensic. Toxicol 2012, 30, 1.
- [10] Kataoka, H.; Ryu, S.; Sakiyama, N.; Makita, M. J. Chromatogr. A 1996, 726, 253.
- [11] Tsunoda, N. J. Chromatogr. A 1993, 637, 167.
- [12] Hori, Y.; Fujisawa, M.; Shimada, K.; Hirose, Y. J. Anal. Toxicol 2001, 25, 680.
- [13] Hori, Y.; Fujisawa, M.; Shimada, K.; Hirose, Y. J. Anal. Toxicol 2003, 27, 162.
- [14] Hori, Y.; Fujisawa, M.; Shimada, K.; Sato, M.; Kikuchi, M.; Honda, M.; Hirose, Y. J. Chromatogr. B 2002, 767, 255.
- [15] Hori, Y.; Fujisawa, M.; Shimada, K.; Sato, M.; Honda, M.; Hirose, Y. J. Chromatogr. B 2002, 776, 191.
- [16] Sancho, J.V.; López, F.J.; Hernández, F.; Hogendoorn, E.A.; van Zoonen, P. J. Chromatogr. A 1994, 678, 59.
- [17] Yoshioka, N.; Asano, M.; Kuse, A.; Mitsuhashi, T.; Nagasaki, Y.; Ueno, Y. J. Chromatogr. A 2011, 1218, 3675.
- [18] http://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Quality/Q2_R1/Step4/Q2_R1_Guideline.pdf. Accessed 28 July 2018.
- [19] http://www.labcompliance.de/documents/FDA/FDA-Others/Laboratory/f-507-bioanalytical-4252fnl.pdf. Accessed 2 March 2018.
Uwagi
PL
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-b3a9957e-22c4-4763-80b1-24cff4e1b435