Thermographic analysis of losses to the surroundings from the WR-25 stoker boiler

Identyfikatory
Warianty tytułu
PL
Analiza termograficzna strat do otoczenia z kotła rusztowego typu WR 25
Języki publikacji
EN
Abstrakty
EN
In this article, the method for calculating the heat loss from the surface of the walls of the power boiler by measuring the temperature distribution on the walls of the boiler with a thermal imaging camera is presented. Measurements were done on two WR25 stoker boilers, with a capacity of 29,1 MW each, working in a heating plant supplying district heating for a town with more than 150 thousand inhabitants. Heat loss from the surface of the boiler walls was calculated, the comparison of heat loss from classic WR25 boiler with loss from water walls-based WR25 boiler was done, a graph of temperature increase along the height of the wall of water walls-based WR25 boiler was made. The analysis and presentation of areas of the highest heat loss (gaps in insulation, uninsulated components on boiler wall) was done.
PL
W artykule zaprezentowano metodę szacowania straty ciepła do otoczenia z powierzchni bocznych analizowanego kotła, poprzez pomiar rozkładu temperatury tych ścian z wykorzystaniem kamery termowizyjnej. Pomiary zrealizowano dla dwóch kotłów rusztowych typu WR 25 o mocy nominalnej 29,1 MW każdy. Kotły zabudowane są w ciepłowni miejskiej zaopatrującej w ciepło ok 150 tys. mieszkańców. Jeden z badanych kotłów był kotłem wykonanym w technologii tradycyjnej drugi w technologii ścian szczelnych. W ramach zrealizowanych prac straty ciepła do otoczenia dla obydwu kotłów zostały oszacowane a wyniki tego oszacowania zestawione. Dodatkowo zidentyfikowano oraz porównano dla obydwu kotłów miejsca występowania lokalnych, podwyższonych strat ciepła.
Wydawca
Czasopismo
Rocznik
Tom
Strony
97--103
Opis fizyczny
Bibliogr. 15 poz., fig., tab
Twórcy
autor
  • Instytut Techniki Cieplnej Politechniki Warszawskiej
  • Instytut Techniki Cieplnej Politechniki Warszawskiej
Bibliografia
  • [1] Carlomagno G. M., Cardone G.: Infrared thermography for convective heat transfer measurements. Experiments in Fluids, December 2010, p. 1187-1218.
  • [2] Cengel Y.: Heat Transfer. A Practical Approach. 2nd ed., McGraw-Hill, 2003.
  • [3] Heselton K.: Boiler Operators Handbook. The Fairmont Press, Inc., 2005.
  • [4] Informator Energetyka, praca zbiorowa, Warszawa 1969 .
  • [5] Krawczyk P., Badyda K.: Numerical analysis of the impact of parameters of urea solution injection on reagent penetration inside the combustion chamber of a WR 25 boiler. Rynek Energii, 2014, 6(104), 115-139
  • [6] Krawczyk P., Badyda K, Szczygieł J, Młynarz S.: Investigation of exhaust gas temperature distribution within a furnace of a stoker fired boiler as a function of its operating parameters. Archives of Thermodynamics 36 (3), 3-14
  • [7] Krishnaswamy K., Ponni Bala M.: Power Plant Instrumentation. New Delhi 2011.
  • [8] Madura H.: Pomiary termowizyjne w praktyce. Warszawa 2004.
  • [9] Serwis internetowy: http://www.mpec.olsztyn.pl/pl/o_firmie/mpec-w-liczbach (15.05.2014).
  • [10] Sukhatme S. P.: A Textbook on Heat Transfer. University Press India 2005.
  • [11] Titman D. J.: Applications of thermography in non-destructive testing of structures. NDT&E International, Volume 34, Issue 2, March 2001, p. 140-154
  • [12] Vollmer M., Mollmann K. P.: Infrared Thermal Imaging: Fundamentals, Research and Applications.John Wiley & Sons, 2010.
  • [13] Więcek B., De Mey G.: Termowizja w podczerwieni. Podstawy i zastosowania. Warszawa 2011.
  • [14] Wiśniewski S., Wiśniewski T.S.: Wymiana ciepła. Warszawa 2009.
  • [15] Wrzesińska B., Krzywda R., Wąsowski T., Krawczyk P., Badyda K.: Technologia selektywnej niekatalitycznej redukcji tlenków azotu pod kątem zastosowania jej w kotłach dla energetyki przemysłowej i ciepłownictwa. Przemysł Chemiczny 94 (4), 608-613
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-b30f91af-6da5-4955-ac2b-b12d0f46d13a
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.