New layout diagrams of combined-cycle power plants, in which some of air compressor stages are rotated not by a gas turbine but by a steam one, are considered. It's showed that if the air compression ratio in the compressor is decreased, the combined-cycle plant efficiency and output power increase; and at some compression ratio increase the combined-cycle power plant (CCPP) can operate with a fully dedicated steamturbocompressor unit.
Czasopismo
Rocznik
Tom
Strony
206--211
Opis fizyczny
Bibliogr. 4 poz., rys., wykr.
Twórcy
autor
autor
autor
- Moscow Power Engineering Institute (Technical University), Moscow Krasnokazarmennaya 14, 11250, Russia, ZariankinAY@mpei.ru
Bibliografia
- [1] A. Zaryankin, A. Rogalev, S. Arianov, S. Storoguk, Thermodynamic basis for passage to CCPP with steam turbine drive of the compressor, Tyazheloe mashinostroenie 12 (2010) 30-37.
- [2] A. Kostuk, A. Sherstuk, Gas turbine unites, Visshaya shkola, Moscow, 1979.
- [3] A. Zaryankin, A. Rogalev, V. Shaulov, S. Storoguk, Different layouts of CCPP with high temperature steam turbines analysis, Gas turbo technology 9 (2009) 46-52.
- [4] A. Kostuk, V. Frolov, A. Bulkin, A. Truhniy, Steam and gas turbines for power plants, Mpei publishers, Moscow, 2008.