PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The application of the Buckingham Π theorem to modeling high-pressure regenerative heat exchangers in off-desing operation

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The study presents the possibility of applying the Buckingham Π theorem to modeling high-pressure regenerative heat exchangers in changed conditions. A list of independent parameters on which the water temperature at the outlet of the heat exchanger depends was selected; and by means of the Buckingham Π theorem a functional relation between two dimensionless quantities, where there is no overall heat transfer coefficient, was obtained. The exact form of the function was determined on the basis of actual measurement data and a linear relation between two dimensionless quantities has been obtained. The correctness of the proposed relation was examined for two high-pressure regenerative exchangers for a 200MW power plant.
Rocznik
Strony
198--205
Opis fizyczny
Bibliogr. 14 poz., rys., wykr.
Twórcy
  • Institute of Heat Engineering, Warsaw University of Technology, 21/25 Nowowiejska Street, 00-665 Warsaw, Poland, rlask@itc.pw.edu.pl
Bibliografia
  • [1] D. Laudyn, M. Pawlik, F. Strzelczyk, Power plants (in Polish), WNT Warszawa, 1995.
  • [2] R. Janiczek, Operation of the steam power plant (in Polish), WNT Warszawa, 1980.
  • [3] T. Hobler, Heat transfer and heat exchangers (in Polish), PWT Warszawa, 1953.
  • [4] E. Radwański, P. Skowroński, A. Twarowski, Problems of modeling of energy systems (in Polish), ITC PW Warszawa, 1993.
  • [5] A. I. Elfeituri, The influence of heat transfer conditions in feedwater heaters on the energy losses and the economical effects of a steam power station, Ph.D. thesis, Warsaw University of Technology (1996).
  • [6] W. Gogół, Heat transfer tables and graphs (in Polish), WPW Warszawa, 1984.
  • [7] L. Kurpisz, Mathematical modeling of regenerative heat exchangers, taking into account the changing conditions of work (in Polish), Ph.D. thesis, Politechnika Warszawska (1972).
  • [8] I. Hussaini, S. Zubair, M. Antar, Area allocation in multizone feedwater heaters, Energy Conversion and Management 48 (2) (2007) 568-575.
  • [9] M. A. Antar, S. M. Zubair, The impact of fouling on performance evaluation of multi-zone feedwater heaters, Applied Thermal Engineering 27 (2007) 2505-2513.
  • [10] T. Barszcz, P. Czop, A feedwater heater model intended for model-based diagnostics of power plant installations, Applied Thermal Engineering 31 (2011) 1357-1367.
  • [11] T. Chmielniak, Flow machines (in Polish), WPŚ, 1997.
  • [12] B. Staniszewski, Heat Transfer (in Polish), PWN Warszawa, 1979.
  • [13] A. Miller, J. Lewandowski, Working steam turbines in the changed conditions (in Polish), WPW Warszawa, 1992.
  • [14] J. Szargut, Thermodynamics (in Polish), PWN Warszawa, 1974.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA9-0051-0026
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.