Characteristic Evaluation of 4mm-square-sized double H-coil

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Podwójna cewka tangencjalna o rozmiarze 4 mm
Języki publikacji
EN
Abstrakty
EN
Two-dimensional vector measurement has become popular as an accurate evaluating method, which can measure the relationship between the magnetic flux density vector B and the magnetic field strength vector H. In order to improve the resolution of the two-dimensional vector magnetic measurement, 4mm-square-sized double H-coil was manufactured and evaluated with a developed evaluation system, which consists of a standard solenoid coil and a high-precision turntable. The V-H sensor combined the H-coil with double needles, was applied to measure distributions of local magnetic characteristics in a model core.
PL
Cewka tangencjalna H-coil jest powszechnie używana do pomiaru pola magnetycznego w badanej próbce. W pracy opisano podwójną cewkę H-coil o rozmiarze 4 mm przeznacz\oną do badania pola magnetycznego z dużą rozdzielczością geometryczną. Cewkę taką sprzężono też z dwoma czujnikami igłowymi do równoczesnego pomiaru indukcji.
Rocznik
Strony
73--76
Opis fizyczny
Bibliogr. 6 poz., rys., tab., wykr.
Twórcy
autor
autor
autor
  • Nishi Nippon Electric Wire & Cable Co., Ltd. R&D department, Kasugaura, Oita 870-0011, aiharas@nnd.co.jp
Bibliografia
  • [1] M. Enokizono, T. Suzuki, J. Sievert and J. Xu, Rotational power loss of silicon steel sheet, IEEE Transactions on Magnetics, (1990), Vol. 26, No. 5, 2562-2564
  • [2] V. Gorican, A. Hamler, M. Jesenik, B. Stumberger, M. trlep, Measurement of alternating magnetic properties of grainoriented materials using a round rotational single sheet tester, Physica B, (2006) Vol. 372, pp. 194-197.
  • [3] W. Brix, K.A. Hempel and F.J. Schulte, Improved method for the investigation of the rotational magnetization process in electrical steel sheets, IEEE Transactions on Magnetics, (2006), Vol. MAG-20, No. 5, pp. 1708-1710
  • [4] K. Senda, M. Ishida, K. Sato, M. Komatsubara, T. Yamaguchi, Experimental evaluation of the accuracy of local magnetic measurement by stylus probe method, Tech. Report of IEE Japan, (1994), MAG-94-71, Vol. 115(1), pp.50-57
  • [5] M. Enokizono, K. Kawamura and J. D. Sievert, New magnetic search coil system for two-dimensional magnetic measurement, Simulation and Design of Applied Electromagnetic Systems, (1994) pp.21-24
  • [6] M. Enokizono, M. Morikawa, K. Kawamura, and J. Sievert: Distribution of two-dimensional magnetic properties in three-phase induction motor model core, IEEE Transactions on Magnetics, (1996), Vol. 32, No. 5, pp. 4989-4991