PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Analiza odpowiedzi dynamicznej wybranych budowli wielopodporowych na nierównomierne wymuszenie kinematyczne

Identyfikatory
Warianty tytułu
Konferencja
Problemy dynamiki konstrukcji / XIII Sympozjum Dynamiki Konstrukcji (XIII ; 25-27 września 2008 ; Rzeszów-Bystre, Polska)
Języki publikacji
PL
Abstrakty
EN
The paper presents analysis of dynamic response of multiple support structures to seismic and mining related paraseismic excitation. Dimensions of the basis of structures are comparable with the length of the wave propagating in the ground and due to it they are exposed to non-uniform kinematic excitation. Calculations of the dynamic response were performed for earth dam at Niedzica and for concrete bridge at LGOM. It was stated that non-uniformity of ground movement may cause significant changes in the dynamic response - both its reduction as well as its growth.
Rocznik
Strony
41--54
Opis fizyczny
Bibliogr. 19 poz., rys., tab., wykr.
Twórcy
autor
  • Politechnika Krakowska im. T. Kościuszki, Wydział Inżynierii Lądowej, Instytut Mechaniki Budowli, 31-155 Kraków, ul. Warszawska 24, jdulinsk@pk.edu.pl
Bibliografia
  • [1] Abdel-Ghaffar A.M., Scott R.F., Craig M.: Full-scale experimental investigation of a modern earth dam, Report EERL 80-02, Pasadena: California Institute of Technology, 1980.
  • [2] Chmielewski T., Zembaty Z.: Podstawy dynamiki budowli, Arkady, Warszawa 1998.
  • [3] Dendrou B., Werner S.: Toridis T.: Three-dimensional response of a concrete bridge system to travelling seismic waves, Computers&Structures, 1985, vol. 20, no.1/3, p. 593-603.
  • [4] Dubiński J., Mutke G.: Ochrona obiektów budowlanych na terenach górniczych, Wydawnictwo GIG, Katowice 1998, s. 533-576.
  • [5] Dulińska J.: Odpowiedź dynamiczna budowli wielopodporowych na nierównomierne wymuszenie parasejsmiczne pochodzenia górniczego, Politechnika Krakowska, Monografia 338, Kraków 2006.
  • [6] Furtak K., Wrana B.: Mosty zintegrowane, Wydawnictwo Komunikacji i Łączności, Warszawa 2005.
  • [7] Harichandran R.S.: Spatial variation of earthquake ground motion. What is it, how do we model it and what are its engineering implications? Dep. of Civil and Environmental Engineering, Michigan State University, 1999.
  • [8] Kiureghian der A.: A coherency model for spatially varying ground motion, Earthquake Engineering and Structural Dynamics, 1996, vol. 25, p. 99-111.
  • [9] Oliveira C.S., Hao H., Penzien J.: Ground motion modeling for multiple-input structural analysis, Structural Safety, 1991, vol. 10, p. 79-93.
  • [10] Papalou A., Bielak J.: Seismic elastic response of earth dams with canyon interaction, Journal of Geotechnical and Geoenvironmental Engineering, 2001, vol. 127, no. 5, p. 446-452.
  • [11] Trifunac M.D., Todorovska M.I., Spectra for differential motion of columns, Earthquake Engineering and Structural Dynamics, 1997, vol. 26, no. 2, p. 251-268.
  • [12] Wang J., Carr A., Cooke N., Moss P.: Effect of spatial variation of seismic input on bridge longintuidal response, 13th Conf. on Earthquake Engineering, no. 640, Vancouver 2004.
  • [13] Wang G., Fu P.C., Zhang J.M.: Seismic response analysis of Gongboxia concrete face rock-fill dam considering nonuniform earthquake input., 11th ICSDEE/3rd ICEGE Proceedings, 2004, Berkley, CA, p. 359-365.
  • [14] Zembaty Z., Cholewicki A., Jankowski R., Szulc J.: Trzęsienie ziemi 30 listopada 2004 r. na Podhalu oraz ich wpływ na obiekty budowlane, Inżynieria i Budownictwo, 2005, nr 9, 507-511.
  • [15] Zembaty Z., Rutenberg A.: Spatial response spectra and site amplification effects, Engineering Structures, 2002, vol. 24, no. 11, p. 1485-1496.
  • [16] Abaqus. Standard User's Manual, 2005.
  • [17] Z_SOIL PC 2003. User Manual. Zace Services Ltd, (http://www.zace.com).
  • [18] Eurokod 8: Earthquake resistant design of structures - second draft 1993 CENT/TC 250/SC8/N85.
  • [19] ISO/DIS 3010, Basis for design of structures - Seismic actions on structures.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA7-0027-0008
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.