In this paper we present a project developed in our University in order to provide Lublin hospitals with efficient software tools for 3D medical image processing and transmission. The system covers the entire image flowpath in the Diagnostic Radiology Department (i.e. image acquisition, processing, archiving, long term storage) and allows transmission of medical images through the Metropolitan Area Network. About 22000 CT examinations have been archived using our system. Over 300 special examinations for radiotherapy planning have been sent to the Lublin's Oncology Centre.
Rocznik
Tom
Strony
IT51--60
Opis fizyczny
Bibliogr. 12 poz., rys.
Twórcy
autor
- Diagnostic Radiology Department, Provincial Specialistic Hospital, Lublin, al. Krasnicka 100
autor
- Diagnostic Radiology Department, Provincial Specialistic Hospital, Lublin, al. Krasnicka 100
autor
- Lublin's Territority Oncology Centre, Lublin, uk. K. Jaczewskiego 8
autor
- TP S.A., Telecommunication Department, Lublin, Pl. Czechowicza 8
autor
- Faculty of Mathematics, Physics and Informatics, UMCS Lublin, Pl. M. Curie-Sklodowskiej 1
autor
- Faculty of Mathematics, Physics and Informatics, UMCS Lublin, Pl. M. Curie-Sklodowskiej 1
Bibliografia
- [1] BENGHIAT A., SAUNDERS V., STEELEW L., Computerizing the Cancer Centre, Clinical Oncology, No. 11, pp 33-39, 1999.
- [2] BIDAUT L., SCHERRER J., Telematics technique for image based diagnosis, therapy planning and monitoring, International Journal of Medical Informatics, No. 52, pp 81-91, 1998.
- [3] COVER T., THOMAS J., Elements of Information Theory, A Wiley-Interscience Publication, New York, 1991
- [4] EVERS H., MAYER A., ENGELMANN U., SCHROTER A., BAUR U., DEMIRIS A., GIESS C., WOLSIFFER A., MEINZER H., Extending a teleradiology system by tools for visualisation and volumetric analysis through a plug-in mechanism, No. 53, pp 265-275, 1999.
- [5] HEAUTOT J.E., EICHELBERG M., GIBOUD B., TREGUIER C., LEMOINE D., SCARBIN J., PIQUERAS J., CARSIN M., GANDON Y., The RETAIN project: dicom teleradiology over an ATM-based network, Eur. Radiol. No. 10, pp. 175-182, 2000.
- [6] LASZEWSKI M., MIKOLAJCZAK P., Lublin Medical Network - NetMed. Conf. Proc. of Research and Development for Information Society, ISThmus 2000, pp. 147-162, Poznań Technical University, Poznań, 2000.
- [7] PRESS W.H., TEUKOLSKY S.A., VETTERLING W.T., FLANNERY B.P., Numerical Recipes in C, Cambridge University Press 1997.
- [8] PRIESTMAN T. J., Equipment, Workload and Staffing for Radiotherapy in the UK. 1992-1997, Board of the Faculty of Clinical Oncology, The Royal College of Radiologists (1998), London, RCF Ref No BFCO(98)2.
- [9] STUDHOLME C., HILL D.L.G., HAWKES D.J., An overlap invariant measure of 3D image alignment, Pattern Recognition vol. 32, no. 1, 1998.
- [10] TAKEDA H., MINATO K., TAKAHASI T., High quality image oriented telemedicine with multimedia technology, International Journal of Medical Informatics, No. 55, pp 23-31, 1999.
- [11] MAINTZ J.B., VIERGEVER M.A., A survey of medical image registration, Medical Image Analysis (1998), vol. 2, nr 1, pp. 1-39, Oxford University Press 1998.
- [12] VIOLA P.A., Alignment by Maximization of Mutual Information, A.I. Technical Report No. 1548, MIT 1995.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA4-0020-0009