Tytuł artykułu

QRS complexes detector for synchronization of ventricular assist device

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Synchronization of operation of an artificial chamber supporting the sick heart of a patient has a crucial meaning for the effectiveness of support. To make the synchronized operation possible, the information on patient's heart activity should be fed to a controller of the supporting chamber. To this end, the QRS complex detector operating on ECG signal is necessary. The signal must be acquired from a patient's heart. Appropriate signal quality at long-term support may be assured only in a case the signal is acquired with epicardial electrodes. In the paper, the concept of hardware construction of a QRS complex detector has been presented, based on a field programmable analog array FPAA. The results of verification of the developed detector include the correct operation while using the epicardial signals recorded from patients which undergone the cardiosurgical operations.
Rocznik
Tom
Strony
35--41
Opis fizyczny
Bibliogr. 11 poz., rys.
Twórcy
autor
  • Institute of Medical Technology and Equipment ITAM, 118, Roosevelt St., Zabrze, Poland
autor
autor
Bibliografia
  • [1] ANADIGM, AnadigmApex dpASP Family User Manual, 2006.
  • [2] ANADIGM, AnadigmDesigner 2 User Manual, 2004.
  • [3] ANADIGM, App Note 206: Automatic Gain Control, 2009.
  • [4] DAVIES J. H., MSP430 Microcontroller Basics, ELSEVIER, 2008.
  • [5] ITAM, MIP-801 Pacemaker – technical documentation, Zabrze, 2003 (not published).
  • [6] MALCHER A., KIDOŃ Z., Some Properties of FPAA-based Analog Signal Processing Applications, The International IFAC Workshop on Programmable Devices and Embedded Systems, 2009, pp. 188–193.
  • [7] MALCHER A., PIETRASZEK S., PRZYBYŁA T., KIDOŃ Z., Real Time QRS Detector Based on Field Programmable Analog Array, Journal of Medical Informatics and Technologies, Vol. 13, 2009, pp. 183–188.
  • [8] MOCHA J., A Comparison of Dynamic Reconfiguration Methods Used in Analog and Digital Programmable Arrays, Proceedings, 9th National Conference of Electronics, Darłówko Wschodnie, 2010.
  • [9] MULAWKA J. J., Układy mikroelektroniczne z przełączanymi pojemnościami, WKŁ, Warsaw, 1987 (in Polish).
  • [10] PAWLICKI G., Fundamentals of Medical Engineering, OWPW, Warsaw, 1997 (in Polish).
  • [11] PN-EN 60601-2-27:2006, Medical electrical equipment, Part 2–27: Particular requirements for the safety, including essential performance, of electrocardiographic monitoring equipment.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA4-0018-0004
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.