Pulse oximetry is a non-invasive measurement method of an arterial blood oxygen saturation. Pulse oximeter is one of the main bedside monitors used in neonatal units. The dispersed location of medical devices in such unit renders impossible to make a fast and valid decision in the case of simultaneous alarming situation. This paper present hardware and software structure of centralised neonatal monitoring system. Presented system can work as a single central station for monitoring of up to twenty four patients. Application of central monitoring system decreases the risk of undetected patients live and health threats. Thanks to this system the medical stuff is less burdened by routine procedures; therefore the medical unit is perceived as child- and mother-friendly.
Słowa kluczowe
Rocznik
Tom
Strony
93--98
Opis fizyczny
Bibliogr. 5 poz., rys.
Twórcy
autor
- Institute of Medical Technology and Equipment, 118 Roosevelt St, 41-800 Zabrze, Poland
autor
- Institute of Medical Technology and Equipment, 118 Roosevelt St, 41-800 Zabrze, Poland
autor
- Institute of Medical Technology and Equipment, 118 Roosevelt St, 41-800 Zabrze, Poland
autor
- Institute of Medical Technology and Equipment, 118 Roosevelt St, 41-800 Zabrze, Poland
autor
- Institute of Medical Technology and Equipment, 118 Roosevelt St, 41-800 Zabrze, Poland
autor
- Institute of Medical Technology and Equipment, 118 Roosevelt St, 41-800 Zabrze, Poland
Bibliografia
- [1] LAING I.A., GRIEVE S.H. ,TARVET F., LOGIE L.J.: Pulse oximetry in newborn intensive care, IEE Colloquium on Pulse Oximetry: A Critical Appraisal, vol. 8, pp.1-3, 1996
- [2] WIDERA M., WRÓBEL J., WIDERA A., MATONIA A.: A method of the ensuring data integrity in the data stream management system, Journal of Medical Informatics & Technologies vol.8, pp.141-148, 2004
- [3] WIDERA M. , JEŻEWSKI J. , WINIARCZYK R. , WRÓBEL J. , HOROBA K. , GACEK A. : Data stream processing in fetal monitoring system: I. Algebra and query language, Journal of Medical Informatics & Technologies, vol.5, pp.83-90, 2003
- [4] WROBEL J., JEZEWSKI J., HOROBA K., GACEK A., GRACZYK S. (1998): System for centralized fetal monitoring, Proc. of the 2nd IMACS CESA '98, pp.772-775, 1998
- [5] L. GOLAB, M.T. OZSU: Issues in data stream management, ACM SIGMOD Record vol.32, pp.5-14, 2003
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA4-0012-0009