PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Baro-paedometric biofeedback for foot unloading procedures investigation

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Numerous studies on new biofeedback devices conception development were undertaken. They are used for some compensation methods of the data lost on sensors set. The aim of the study was carried out for introducing several approaches of investigations and testing of the biofeedback devices that support a plantar pressure analysis, for foot unloading processes implementation. The healthy man is walking in normal conditions first; on a walkway. The recorded load on 6 sensors has to be reduced next in a specified area. The pressure was considered at the beginning on metatarsal head, in time of 100 steps. The visual and auditory signals were then adjusted to a specific plantar pressure threshold setting. The peak pressure was evaluated for various walking condition. The introduced device enables us reducing the peak plantar pressure within the appointed risk-regions.
Rocznik
Tom
Strony
41--45
Opis fizyczny
Bibliogr. 7 poz., rys., tab.
Twórcy
  • Universite de Lille 2.9, rue de I'Universite, 59790 Ronchin, France
autor
Bibliografia
  • [1] DESCATOIRE A, FEMERY V, MORETTO P. Plantar pressure redistribution after a high and low unload, J. of biomechanics, vol. 40, pp.S177, 2007.
  • [2] FEMERY V, MORETTO P, HESPEL JM, THEVENON A, LENSEL G. A real-time plantar pressure feedback device for foot unloading, Arch Phys Med Rehabil, vol. 85, pp.1724-8, 2004.
  • [3] NURSE MA, NIGG BM. Quantifying a relationship between tactile and vibration sensitivity of the human foot with plantar pressure distributions during gait, Clin Biomech, vol. 14, pp.667-72, 1999.
  • [4] TAYLOR A, MENZ H, KEENAN A. Effect of experimentally induced plantar insensitivity on forces and pressures under the foot during normal walking, Gait and Posture, vol. 20, pp.232-7, 2004.
  • [5] PIECHA J. “The foot abnormality diagnostics and expertise” 20th Int. Conf. Information Technology Interfaces ITI’98, June 16-19, Pula, Croatia, pp.137-142, ISSN 1330-1012.
  • [6] PIECHA J.: The neutral network selection for a medical diagnostic system using an artificial data set. Journal of Computing and Information Technology CIT, Vol.9, pp: 123–132, 2001.
  • [7] MUELLER MJ, LOTT DJ, HASTINGS MK, COMMEAN PK, SMITH KE, PILGRAM TK. Efficacy and mechanism of orthotic devices to unload metatarsal heads in people with diabetes and a history of plantar ulcers, Phys Ther, vol. 86, pp.833-42, 2006.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA4-0007-0003
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.