PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The prognostic value of electrohysterography in prediction of premature labour

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Premature birth is the leading cause of a neonatal death, so, it is extremely important to distinguish the pregnancy at risk of preterm threatening labour. The electrohysterography seems very promising as a method which enables noninvasive recording of readable bioelectrical signal of uterine muscle. The developed instrumentation enabled simultaneous recording of bioelectrical signals by means of electrodes attached to abdominal wall and mechanical activity of uterine muscle using fetal monitor. Material comprised 27 patients in physiological pregnancy (27 ÷ 40 week), and 21 patients (23 ÷ 36 week) with the symptoms of threatening premature labour. The obtained results showed that quantitative parameters of detected uterine contractions: amplitude and contraction area, obtained both for mechanical and electrical activity, were statistically significant (p < 0.05) to distinguish the patients at risk of premature labour. However, their reliability is low because they strongly depend on individual patient features. We consider the parameters characteristic for electrohysterogram exclusively e.g. contraction power and its median frequency as more useful (p < 0.05). Noninvasive electrohysterography ensures higher sensitivity and specificity for recognition of uterine contraction activity in comparison to classical mechanical method.
Rocznik
Tom
Strony
71--76
Opis fizyczny
Bibliogr. 5 poz., rys., tab.
Twórcy
autor
  • Medical University of Silesia/Department of Obstetrics and Gynecology, Katowice, Poland
autor
autor
autor
autor
Bibliografia
  • [1] HARRISON A., CROWE .J A., HAYES-GILL B. R., VAN WIJNGAARDEN W., Use of the electrohysterogram for uterine contraction monitoring during labour, Proc. 3rd Eur. Conf. on Eng. and Med., pp. 90, 1995.
  • [2] JEZEWSKI J., et al., Centralised fetal monitoring system with hardware-based data flow control, Proc. of III Int. Conference MEDSIP, pp. 51–54, Glasgow, 2006.
  • [3] JEZEWSKI J., HOROBA K., MATONIA A., WRÓBEL J., Quantitative analysis of contraction patterns in electrical activity signal of pregnant uterus as an alternative to mechanical approach, Physiol Meas, Vol. 26, pp. 753–767, 2006.
  • [4] MANER W. L., et al., Predicting term and preterm delivery with transabdominal uterine electromyography, Obstet Gynecol, Vol. 101, pp.1254–1260, 2003.
  • [5] MATONIA A., et al., Computer aided fetal monitoring system using noninvasive electrocardiogram, IFMBE Proc. 13th Nordic Baltic Conference Biomed. Eng. Med. Phys., Vol. 9, pp. 313–314, Umea, Sweden, 2005.