PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

State-space averaging for maternal ECG suppression

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In this paper a new method of maternal electrocardiogram suppression for fetal component extraction from one-channel maternal abdominal bioelectric signals is proposed. The method performs maternal ECG estimation by application of state-space averaging. The estimated signal is subtracted from the original one and this way suppressed. The method parameters allow us to balance between the precision of maternal ECG suppression and the necessity not to attenuate the fetal QRS complexes. A small database of the maternal abdominal bioelectric signals is used to investigate the developed system for fetal heart rate determination. The final assessment is based on the detection performance index. It is shown that by proper choice of the parameters we can tune the system so that it is more effective than the classical approach based on template subtraction.
Rocznik
Tom
Strony
194--200
Opis fizyczny
Bibiliogr. 9 poz., rys., tab.
Twórcy
autor
  • Institute of Electronics, Silesian University of Technology, Gliwice, Poland
autor
autor
autor
Bibliografia
  • [1] CALLAERTS D., De MOOR B., VANDEVALLE J., et al., Comparison of SVD methods to extract the foetal electrocardiogram from cutaneous electrode signals, Med Biol Eng Comp, 1990, pp 217-224.
  • [2] DE LATHAUWER L., CALLAERTS D., DE MOOR B., VANDEWALLE J., "Fetal electrocardiogram extraction by source subspace separation," Proc. IEEE SP/ATHOS Workshop on HOS, Girona, Spain, 1995, pp.134-138.
  • [3] JEŻEWSKI J., WRÓBEL J., HOROBA K., Comparison of Doppler Ultrasound and Direct Electrocardiography Acquisition Techniques for Quantification of Fetal Heart Variability, IEEE Trans. Biomed. Eng., vol. 53, 2006, pp. 855-864.
  • [4] KOTAS M., Application of dynamic time warping to ECG processing, Proc. Int. Conf. MIT, Poland, IX 2006, pp. 169-175.
  • [5] KOTAS M., Projective filtering of time warped ECG beats, Computers in Biology and Medicine, Vol. 38, No. 1, pp. 127-37.
  • [6] KOTAS M., Combined application of independent component analysis and projective filtering to fetal ECG extraction, Biocyb. Biomed. Eng., vol. 28, 2008, pp. 75-93.
  • [7] KOTAS M., JEŻEWSKI J., KUPKA T., HOROBA K., Detection of low amplitude fetal QRS complexes, Proc. of 30th IEEE/EMBS Conf., 2008, pp. 4764-4767.
  • [8] MATONIA A., JEŻEWSKI J., HOROBA K., GACEK A., The Maternal ECG Suppression Algorithm for Efficient Extraction of the Fetal ECG from Abdominal Signal, Proc. IEEE EMBS Conf., New York City, USA, 2006, pp. 3106-3109.
  • [9] SCHREIBER T., Extremely simple nonlinear noise-reduction method, Physical Review E, Vol.47, No. 4, 1993, pp. 2401-2404.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA4-0002-0034
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.