PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Real time QRS detector based on field programmable analog array

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In some applications it is important to detect the QRS complex in the ECG waveform with possibly low time delay. Traditional software detectors of the QRS complex implement algorithms usually based on cascades of digital filters that introduce delays up to parts of a second. On the other hand, hardware QRS detectors fulfil the low delay requirements, but have worse adaptive features for the changing ECG shape. In this paper a new approach to QRS detection is presented. The proposed detector is based on a Field Programmable Analog Array (FPAA). This solution makes it possible to modify the parameters of particular blocks of the detector or even the whole structure without any changes in hardware, while the processing path is fully analog and does not introduce an additional delay. The most interesting feature of the FPAA is the dynamic reconfigurability. The parameters can be changed during runtime without any reset of the circuit or any other disturbances of the system functionality. The prototype QRS detector was built using the AN221E04 circuit from the Anadigm company.
Rocznik
Tom
Strony
183--188
Opis fizyczny
Bibliogr. 9 poz., rys., tab.
Twórcy
autor
  • Institute of Electronics, Silesian University of Technology, ul. Akademicka 16, 44-100 Gliwice. Poland
autor
autor
Bibliografia
  • [1] BARANOWSKIJ A.L., NIEMIRKO A.P.: Kardiomonitory Aparatura Nieprerywnogo Kontrola EKG, Radio i Swiaz, Moskwa, pp. 72-87, 1993.
  • [2] AUGUSTYNIAK P., Przetwarzanie sygnałow elektrodiagnostycznych, Uczelniane Wydawnictwa Naukowo-Dydaktyczne AGH, Kraków, pp. 141-147, 2001.
  • [3] MOODY, G.B.; MARK, R.G.; GOLDBERGER, A.L., PHYSIONET: A Web-Based Resource For The Study Of Physiologic Signals, Engineering in Medicine and Biology Magazine, IEEE, Vol. 20, Issue 3, pp. 70-75, May-June 2001.
  • [4] MIT-BIH Arrythmia Database: http://www.physionet.org/physiobank/database/mitdb/
  • [5] AN221E04 Field Programmable Analog Arrays - User Manual (2008) http://www.anadigm.com/_doc/UM021200-U007.pdf
  • [6] AN221E04 Datasheet, Dynamically Reconfigurable FPAA with Enhanced I/O (2008) http://www.anadigm.com/_doc/DS030100-U006.pdf
  • [7] AN221K04 v3 development board User Manual (from dec06): http://anadigm.com/_doc/UM022100-K003.pdf
  • [8] IAR Embedded Workbench: http://iar.com/website1/1.0.1.0/50/1/
  • [9] National Instruments LabVIEW Homepage: http://www.ni.com/labview/
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-PWA4-0002-0032
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.