Identyfikatory
Warianty tytułu
Eksploatacja przemysłowa biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC
Języki publikacji
Abstrakty
The paper discusses three years' commercial operation to date of the Biogas Cogeneration Set driven with the JMS 316 GS-B.LC GE JENBACHER type engine, which has been operating in the WARTA S.A. Sewage Treatment Plant of Czestochowa since the end of December 2008. The analysis covered the CHP Set's operation and shutdown times, number of start-ups and availability, electric energy and heat generation, and average hourly electric and thermal load; the Sewage Treatment Plant's electric energy and heat balance and the degree of coverage of its electric energy and heat demand by its own production; the unit biogas consumption by the CHP Set; the service work carried out on, and failures of the CHP Set; and the economic effects gained from the operation of the Set. The study is a continuation of the authors' previous publications [3, 6, 7, 8] and, jointly with them, constitutes a unique compendium of knowledge for future operators of CHP biogas sets in the form of a collection of actual operational data for one of the most representative biogas cogeneration sets operated in domestic sewage plants in terms of electric power (approx. 0.8 MW).
W artykule omówiono dotychczasową, trzyletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracującego od końca grudnia 2008 r. w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę rozruchów i jego dyspozycyjność, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, także bilans energii elektrycznej i ciepła oczyszczalni oraz stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, jednostkowe zużycie biogazu przez zespół kogeneracyjny, prace serwisowe i awarie zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu. Praca jest kontynuacją wcześniejszych publikacji autorów [3, 6-8] i łącznie z nimi stanowi unikatowe kompendium wiedzy dla przyszłych eksploatatorów biogazowych zespołów CHP w postaci zbioru rzeczywistych danych eksploatacyjnych, jednego z najbardziej reprezentatywnych pod względem mocy elektrycznej (ok. 0,8 MW) biogazowego zespołu kogeracyjnego eksploatowanego w krajowych oczyszczalniach ścieków.
Czasopismo
Rocznik
Tom
Strony
57--70
Opis fizyczny
Bibliogr. 27 poz.
Twórcy
autor
- Faculty Mechanical Engineering and Computer Science at the Czestochowa University of Technology, Poland, duzynski@imc.pcz.czest.pl
Bibliografia
- [1] Cupiał K., Dużyński A.: Dorobek Instytutu Maszyn Tłokowych i Techniki Sterowania Politechniki Częstochowskiej w dziedzinie konstrukcji, badań i eksploatacji silników gazowych. Silniki Gazowe – wybrane zagadnienia. Monografia pod red. Dużyńskiego A. Wydawnictwo Politechniki Częstochowskiej, Częstochowa 2010.
- [2] Cupiał K., Dużyński A., Grzelka J.: A summary of the eight years of operation of the biogas heat and power-generating set in the Waste Treatment Plant of WARTA S.A. in Częstochowa. Combustion Engines 1/2006 (124).
- [3] Cupiał K., Dużyński A., Grzelka J., Bawor W.: Podsumowanie sześciomiesięcznej eksploatacji nowego biogazowego zespołu kogeneracyjnego w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Współczesne problemy energetyki gazowej i gazownictwa. Monografia pod red. Kaliny J., Kotowicza J., Skorka J., Walewskiego A. Energetyka Gazowa 2009. Wyd. Instytutu Techniki Cieplnej, Gliwice 2009.
- [4] Cupiał K., Dużyński A., Grzelka J., Mendera K.: Biogazowy zespół prądotwórczy o mocy elektrycznej 600 kW z utylizacją ciepła. Journal of KONES – Internal Combustion Engines – Warszawa–Zakopane 1999, vol. 6, nr 3–4, Scientific Publication of Permanent Committee of KONES, Kraków 1999.
- [5] Dużyński A.: Analiza rzeczywistych parametrów techniczno-eksploatacyjnych gazowych zespołów kogeneracyjnych. Politechnika Częstochowska, seria Monografie nr 142. Częstochowa 2008.
- [6] Dużyński A.: Technological and economic aspects of two year’s operation of the biogas cogeneration set at the WARTA S.A. waste treatment plant in Czestochowa, Poland, s. 25-35. Power Engineer. Journal of the IDGTE. Vol. 16, Issue 1, The Institution of Diesel and Gas Turbine Engineers, Bedford, UK, 2012. ISSN-1367-191x.
- [7] Dużyński A., Bawor W.: A Summary of the twelve month’s operation of the new biogas cogeneration set in the WARTA S.A. Waste Treatment Plan in Częstochowa. Combustion Engines 2/2010 (141).
- [8] Dużyński A., Bawor W.: Experience from two years’ operation of the Biogas Cogeneration Set at the WARTA S.A. Waste Treatment Plant in Częstochowa. Combustion Engines 3/2011(146).
- [9] Elsenbruch T.: GE ENERGY Jenbacher gas engine technology – preventive maintenance by means of highly sophisticated control systems. Combustion Engines 2/2006 (125).
- [10] Kalmbach S., Schmölling J.: Technische Anleitung zur Reinhaltung der Luft – TA Luft. TA Luft mit Erläuterungen. Erich Schmidt Verlag GmbH & Co., Berlin 2004.
- [11] Dziennik eksploatacyjny biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER JMS 316 GS-B.LC za okres 12.2008-31.12.2011. Materiały wewnętrzne Oczyszczalni Ścieków WARTA S.A. w Częstochowie.
- [12] GE JENBACHER Documentation JMS 316 GS-B/LC – wersja 2004.01.
- [13] Instrukcja techniczna nr 1000-0300. Jakość gazu pędnego. GE JENBACHER Documentation. 08.2005.
- [14] Jenbacher gas engines. Technical Specification. JMS 316 GS-B.L. GE JENBACHER GmbH & Co. OHG, www.cogeneration.com.ua/img/zstored/J316V21_en.pdf – 09.2011.
- [15] Jurajski Produkt Roku. Regionalna Izba Przemysłowo-Handlowa w Częstochowie. Częstochowa 2010. www.blachownia.pl/2011/207-jurajski/jpr2010.pdf – 09.2011.
- [16] Modernizacja gospodarki energetycznej i cieplnej z zastosowaniem odnawialnych źródeł energii na centralnej oczyszczalni ścieków eksploatowanej przez Oczyszczalnię Ścieków WARTA S.A. w Częstochowie. Zespół prądotwórczy. Projekt wykonawczy. II. Część technologiczna. BIPROWOD-Warszawa Sp. z o.o. Warszawa, luty 2008 r.
- [17] Oczyszczanie gazu absorberami węgla aktywnego – JENBACHER Energie.
- [18] Rynek Praw Majątkowych, www.tge.pl; www.polpx.pl, 05.2012.
- [19] www.cire.pl/GE 05.2012.
- [20] www.ekonaft.com.pl/mobil_last/przemyslowe-mobil/n06_do_silnikow_gazowych/full-mobil-pega-sus610.htm, 06.2009.
- [21] www.nergia.rzeszow.pl/index.php?option=com_content&view=article&id=94:systemy-scada-w-sterowaniu-procesami-technologicznymi&catid=45:potencja-c-net, 10.2012.
- [22] www.fluke.com/fluke/plpl/Portable-Oscilloscopes/Fluke-120.htm?PID=55999, 10.2012.
- [23] www.fresenius-ut.com/download/DB_BIOGASv2.pdf, 10.2012.
- [24] www.landis.com, 09.2012.
- [25] www.plcs.net.pl/index.php/nowosci-ze-swiata-automatyki/praktyczne-rozwiazania-automatyki/systemy-scada-wstep.html, 10.2012.
- [26] www.tauron-dystrybucja.pl/r/res/taryfa/Taryfa_TAURON_Dystrybucja_2012.pdf, 05.2012.
- [27] www.wartasa.eu, 01.2012.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-LODC-0005-0006