PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Finite element analysis on the flexural behaviour of concrete filled steel tube beams

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Metoda elementów skończonych w badaniu właściwości stalowych kolumn
Języki publikacji
EN
Abstrakty
EN
Concrete-filled steel tube (CFST) beams are studied and verified by the Finite Element program ANSYS against experimental data. In the nu- merical analysis, the cross sections of the CFST are square steel sections, and sections strengthened by being filled with normal mix concrete and quarry waste concrete. Numerical analyses have shown that for square CFST a good confining effect can be provided. This effect is enhanced especially by the filling.
PL
W pracy przedstawiono analizę porównawczą wyników eksperymentalnych i otrzymanych z metody elementów skończonych (ANSYS) w odniesieniu do kolumn zbudowanych ze stalowych rur wypełnionych betonem (CFTS). Analizę numeryczną przeprowadzono dla kolumn o przekroju kwadratowym wzmacnianym normalną mieszanką betonową oraz betonem zawierającymodpady z kamieniołomu. Rezultaty symulacji numerycznych pokazały, że dla kolumn CFTS o przekroju kwadratowym uzyskuje się dobry efekt wzmocnienia wynikający z wypełnienia.
Rocznik
Strony
505--516
Opis fizyczny
Bibliogr. 11 poz., rys., tab.
Twórcy
autor
Bibliografia
  • 1. Al-Rodan A., Al-Tarawnah, 2003, FE analysis of the flexural behaviour of rectangular tubular sections filled with high strength concrete, Emirates Journal for Engineering Research, 8, 1, 71-77
  • 2. Arivalagan S., Kandasamy S., 2008, Flexural behaviour of concrete-filled SHS beams, Journal of Civil Engineering and Managemet, 14, 2, 107-114
  • 3. BS5400, 1979, (Part 5), Concrete and Composite Bridges; Code of Practice for Design of Composite Bridges, British Standards Institution, London
  • 4. Chen C.C., Li H.L., 2001, Finite element analyses of steel beam to concretefilled circular steel tube column connections, Proceedings of the Eighth International Conference on the Application of Artificial Intelligence to Civil and Structural Engineering Computing, Stirling, Scotland, 171-172
  • 5. EUROCODE 4, 1999, (Part 1.1), Design of composite steel and concrete structures, general rules and rules for buildings, British Standards Institution, London
  • 6. Han L.-H., Huo J.-S.,Wang Y.-C., 2007, Behavior of steel beam to concretefilled steel tubular column connections after exposure to fire, Journal of Structural Engineering, 133, 6, 800-814
  • 7. Hu H.T., Huang C.S., Wu M.H., Wu T.M., 2003, Nonlinear analysis of axially loaded concrete-filled tube columns with confinement effect, Journal of Structural Engineering, ASCE, 129, 10, 1322-1329
  • 8. Lakshmi B., Shanmugam N.E., 2002, Nonlinear analysis of in-filled steel-concrete composite columns, Journal of Structural Engineering, ASCE, 128, 7, 922-933
  • 9. Liang Q.Q., Uy B., Bradford M.A., Ronagh R.H., 2005, Strength analysis of steel-concrete composite beams in combined bending and shear, Journal of Structural Engineering, ASCE, 131, 10, 1593-1600
  • 10. Liang Q.Q., Uy B., Liew J.Y.R., 2007, Local buckling of steel plates In concrete-filled thin-walled steel tubular beam-columns, Journal of Constructional Steel Research, 63, 26, 750-760
  • 11. Szlendak J.K., 2004, Strength and stiffness of RHS beam to RHS concrete filled column joints, Proceedings of the Fifth International Conference on Connections in Steel Structures, Bialystok Technical University, Poland, 1024-1036
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWM7-0002-0028
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.