Selected problems concerning strength of a floating dock with roof

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents models and results of the structural strength analysis of a roofed floating dock. Computed thickness of the roof structure walls capable of withstanding the environmental loads is 24 mm. Heavy sliding roof segments generate the dock pontoon floor plate stresses reaching 25% of the permissible stress value. The dock pontoon structure effort under the roof and docked ship weight load was minimized by seeking an optimum balancing ballast distribution. The problem was solved in two ways: analytically, by means of a simplified model of a continuous beam on elastic foundation and numerically, using the linear programming method to construct an accurate discrete FEM model.
Rocznik
Tom
S 1
Strony
51--55
Opis fizyczny
Bibliogr. 5 poz., rys., tab.
Twórcy
autor
autor
autor
  • Gdańsk University of Technology
Bibliografia
  • 1. Polish Register of Shipping : Rules for the classificationandconstructionoffloatingdocks. Gdańsk, 1987
  • 2. Polish standard PN – 80/B – 02010 : Loads in structural analysis. Snow loads
  • 3. Polish standard PN – 77/B – 02011 : Loads in structural analysis. Wind loads
  • 4. Polish standard PN – 90/B – 03200 : Steel structures. Structural analysis and design
  • 5. Konieczny L., Kurski W., Wituszynski K.: Exercises in the ship structural mechanics - Part 1. Gdańsk University of Technology. Gdańsk, 1967