Tytuł artykułu
Identyfikatory
Warianty tytułu
Wpływ konstrukcji elektrokatalitycznych czujników gazów toksycznych na ich właściwości
Konferencja
31 International Conference and Exhibition IMAPS Poland 2007 ; 23-26.09.2007 ; Rzeszów - Krasiczyn, Poland
Języki publikacji
Abstrakty
In this paper the study on the influence of sensor construction on its performance is presented. Properties of sensors prepared with thick film and ceramic technologies will be compared. Thick film sensors were prepared with electrolyte layer and electrodes screen printed on the alumina substrate. Sensors prepared in ceramic technology were in the form of pellets. Lisicon was used as solid state electrolyte. Measurements were conducted in mixtures of high purity gases: nitrogen dioxide, sulphur dioxide and synthetic air of controlled concentration in wide range of temperatures.
Przedstawiono wyniki badań wpływu konstrukcji czujnika na jego właściwości. Porównano właściwości czujników wykonanych w technologiach ceramicznej i grubowarstwowej. Czujniki grubowarstwowe przygotowano poprzez nałożenie kolejno warstw elektrod i elektrolitu na alundowe podłoże. Czujniki przygotowane w technologii ceramicznej miały formę pastylek z elektrodami po obu stronach. Jako elektrolit wykorzystano Lisicon, elektrolit stały z mobilnymi jonami litu. Badania przeprowadzono w mieszaninie o kontrolowanym składzie wysokiej jakości gazów: dwutlenku azotu, dwutlenku siarki, dwutlenku węgla i syntetycznego powietrza w szerokim zakresie temperatur.
Wydawca
Rocznik
Tom
Strony
65--67
Opis fizyczny
Bibliogr. 9 poz., wykr.
Twórcy
autor
autor
autor
autor
- Gdansk University of Technology, Faculty of Electronics, Telecommunications and Informatics
Bibliografia
- [1] Liu J., Weppner W.: Θ - sensors: a new concept for advanced solid-state ionic gas sensors. Applied Physics A, 55 (1992) 250.
- [2] Shoemaker E. L., Vogt M. C., Dudek F. J.: Cyclic voltammetry applied to an oxygen-ion-conducting solid electrolyte as an active electrocatalytic gas sensor. Solid State Ionics, (1996) 285.
- [3] Jasiński P., Nowakowski A., Weppner W.: Kinetic studies of Nasicon based sensors with cyclic voltammetry. Sensors and Materials, 12 (2000) 89-97.
- [4] Jasiński G., Jasiński P., Nowakowski A., Chachulski B.: Thick film Lisicon sensor with gold electrodes. Proc. of 28th IMAPS-Poland Conference, Wroclaw, September, 269.
- [5] Shoemaker E. L., Vogt M. C., Dudek F. J., Turner T.: Gas microsensors using cyclic voltammetry with a cermet electrochemical cell. Sensors and Actuators B, (1997) 1.
- [6] Jasiński G., Jasiński P., Chachulski B., Nowakowski A.: "Application of ceria electrolyte in electrocatalytic gas sensor", Proceedings of 27th IMAPS-Poland Conference, Podlesice-Gliwice, September 2003, 185.
- [7] Jasiński G., Jasiński P., Chachulski B., Nowakowski A.: Lisicon solid electrolyte electrocatalytic gas sensor. Journal of the European Ceramic Society, (2005) 2969.
- [8] Jasiński P., Nowakowski A.: "Simultaneous detection of sulfur dioxide and nitrogen dioxide by Nasicon sensor with platinium electrodes", Ionics, 6 (2000) 230-234.
- [9] Hong H. Y.-P.: Crystal structure and ionic conductivity of Li14Zn(GeO4)4 and other new Li3 superionic conductor. Materials Research Bulletin, 13 (1978) 117.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWAP-0004-0097