Tytuł artykułu
Autorzy
Identyfikatory
Warianty tytułu
Mikroprocesorowy bezprzewodowy system monitorowania i przetwarzania postmortalnych parametrów
Języki publikacji
Abstrakty
The article is presented microprocessor system for tracking and processing of post-mortal parameters of an object-potentials and temperature characteristic parameters of the environment, to increase efficiency is to encrypted wireless communication. It is known that the importance of development and implementation of effective methods and technologies in forensics to improve the quality of technological operations and accuracy of the results and conclusions. Proceeding from the premise that the determination of age of death proof may be noted that results from the development of an electronic system to diagnose the condition of the site will be of interest from medical, judicial and social terms.
Medycyna sądowa jest nauką stosowaną, mającą za zadanie pomagać prawnikom. Opracowanie i wdrożenie skutecznych metod i technologii jest bardzo ważne dla poprawy jakości działalności technologicznych i dokładności wyników i wniosków w medycynie sądowej. Dlatego elektroniczny system, za pomocą którego można dokładnie i obiektywnie ustalić czas w jakim doszło do zgonu, będzie bardzo pomocnym i wiarygodnym sprzętem w medycynie sądowej. W niniejszym opracowaniu jest przedstawiony mikroprocesorowy system monitorowania i przetwarzania postmortalnych parametrów obiektu (potencjały i temperatury) oraz charakterystyczne parametry środowiska, za pomocą których można ustalić dokładny czas zgonu. Dla usprawnienia wydajności systemu zastosowano szyfrowana, komunikację bezprzewodową.
Wydawca
Rocznik
Tom
Strony
105--109
Opis fizyczny
Bibliogr. 13 poz., tab., wykr.
Twórcy
Bibliografia
- [1] AAMI, American National Standard, Safe Current Limits for Electromedical Apparatus ANSI/AAMI ES1-1993). Association for the Advancement of Medical Instrumentation, 1993.
- [2] Botezatu G., Teterchev V. and Ungurqn S.: Diagnosis of the age of death in forensic. Shtiintsa, Russia, 1987.
- [3] Dobrev D.: Two-electrode low supply voltage electrocardiogram signal amplifier. Medical & Biological Engineering Scomputing, 42(2): 272-6, 2004.
- [4] Dobrev D. P., Neycheva T., Mudrov N.: Bootstrapped two-electrode biosignal amplifier. Med. Biol. Eng. Comput., 2008, 46(6), 613-619.
- [5] Firth J. and P. Errico: Low-Power, Low-Voltage 1C Choices for ECG System Requirements. Analog Dialogue, vol. 29, Numbers, 1995.
- [6] Gromov A., Kapustin B.: Forensics examination of the corpse. 1991.
- [7] Ko Keun Kim, Yong Kyu Lim, and Kwang Suk Park.: Common Mode Noise Cancellation for Electrically Non-Contact ECG Measurement System on a Chair. In 27th Annual International Conference of the IEEE EMBS, pp. 5881-5883, Shanghai, September 2005.
- [8] Kyle G. U. et al.: Bioelectrical Impedance Analysis-part I: review of principles and methods. Elsevier, no. 23, pp. 1226-1243, 2004.
- [9] Matic N.: PIC microcontrollers. E-Books. MiKroElektronika, 2003.
- [11] Radanov S.: Forensic medicine and medical deontology. Ciela, Sofia, 2006, p. 621.
- [12] Varun Chandola, Arindam Banerjee, and Vipin Kumar: Anomaly detection. ACM Computing Surveys, 41(3): 1-58, 2009.
- [13] Webster John G.: Medical Instrumentation. Application and Design. 3rd edition, Wiley, 1998.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWAN-0008-0028