Purpose: The aim of the work was determination of influence of the selected methods of bone union electrostimulation on corrosion of Ti6Al4V ELI alloy implants. Design/methodology/approach: In vitro tests were carried out with the use of different methods of electrostimulation-invasive, semi-invasive and non-invasive. The alternating current without constant component was applied. The influence of electrostimulation on corrosion of implants was evaluated on the basis of the mass measurements and surface observations. Findings: On the basis of the research no significant corrosion on the samples was observed. Only local surface etching was observed, however it didn't cause measurable change of mass. The presence of metallic ions in the solution was revealed. Research limitations/implications: Lack of visible and measurable corrosion requires the change of the methodology. Further research should be focused on the amount of metallic ions dissolved from the implants. Furthermore, it should be emphasized that the absence of corrosion of the electrostimulated implants is only one of many criteria describing the usefulness of electrostimulation parameters. The basic criterion is the biological effect obtained as the result of the electrostimulation. Practical implications: The obtained results are the basis for selection of methods and current parameters of the bone union electrostimulation in further clinical research (for stabilizing elements made of titanium alloys). Positive results of the in vitro research confirmed in tests in animals can enable further clinical tests. Positive results of the clinical tests could enable the bone union electrostimulation applied in pathological fractures in patients allergic to Cr. Allergy to Cr and Ni limits a wide use of implants made of Cr-Ni-Mo steel. Originality/value: The paper is a continuation of the research on determining safe parameters of bone union electrostimulation of implants made of stainless steel coated with the passive and passive-carbon layers.
Wydawca
Rocznik
Tom
Strony
27--30
Opis fizyczny
Bibliogr. 15, il., tab.
Twórcy
autor
autor
autor
- Division of Biomedical Engineering, Institute of Engineering Materials and Biomaterials, Silesian University of Technology, ul. Konarskiego 18a, 44-100 Gliwice, Poland, janusz.szewczenko@polsl.pl
Bibliografia
- [1] J. Marciniak, Biomaterials. Publishig House of Silesian Technical University, Gliwice, 2002. (in Polish).
- [2] ASTM F136-98.
- [3] J. Adamus, Forming of the titanium implants and medical tools by metal working, Archives of Materials Science and Engineering 28/5 (2007) 313-316.
- [4] A. Kierzkowska, M. Malinowski, E. Krasicka-Cydzik, Effect of bending on anodized Ti6Al4V alloy: I. Surface layers characteristics, Journal of Achievements in Materials and Manufacturing Engineering 18 (2006) 139-142.
- [5] C. Sittig, M. Textor, N. D. Spencer, M. Wieland, P. H. Vallotton, Surface characterization of implant materials CP Ti, Ti-6Al-7Nb, Ti-6Al-4V with different pretreatments. Journal of Materials Science: Materials in Medicine 10/1 (1999) 35-46.
- [6] J. Szewczenko, Electric phenomena in long bone. Electro-technical Review 12 (2005) 94-97 (in Polish).
- [7] J. Anglen, Enhancement of fracture healing with bone stimulators. Techniques in Orthopeadics 17/50 (2002) 6-14.
- [8] K. Yonemori, S. Matsunaga, Y. Ishidou, S. Maeda, H. Yoshida, Early effects of electrical stimulation on osteogenesis, Bone 19 (1996) 173-80.
- [9] D. Hannouche, H. Petite, L. Sedel, Current trends in the enhancement of fracture healing, Journal of Bone and Joint Surgery-British 83 (2001) 157-64.
- [10] M. Hinsenkamp, F. Burny, J. Jedwab, R. Bourgois, Corrosion of implants during electric stimulation of fracture healing, in electrical stimulation of bone growth and repair, F. Burny, E. Herbst, M. Hinsenkamp, Springer-Verlag, Berlin, Heidel-berg, 1978.
- [11] J. Szewczenko, J. Marciniak, Corrosion of Cr-Ni-Mo steel implants electrically stimulated, Journal of Materials Processing Technology 175 (2006) 404-410.
- [12] W. Chrzanowski, Corrosion behavior of Ti6Al7Nb alloy after different surface treatments, Journal of Achievements in Materials and Manufacturing Engineering 18 (2006) 67-71.
- [13] W. Chrzanowski, J. Marciniak, L. F. Ciupik, G. Nawrat, Evaluation of usefulness of electrochemical treatment for spine implants surface modification, Biomaterials Engineering 46 (2005) 12-15.
- [14] J. Marciniak, W. Chrzanowski, G. Nawrat, J. Żak, B. Rajchel, Structure modification of surface layers of Ti6Al4V ELI implants, Key Engineering Materials 254-256 (2004) 387-390.
- [15] J. Szewczenko, J. Marciniak, W. Chrzanowski, Corrosion of Cr-Ni-Mo steel implants in conditions of sinusoidal current electrostimulation. Proceedings of the 9th International Scientific Conference „Achievements in Mechanical and Materials Engineering” AMME'2000, Gliwice-Sopot-Gdańsk, 2000, 511-514.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWAN-0003-0005