In the paper the way of establishment of operational characteristics of Mechelle 900 spectrometer equipped with fast SensiCamFS camera of down to 100 ns time exposure is described. The overall responsivity of spectrometer-camera set was found and radiometric calibration procedure and calibration curve were developed and determined. Exemplary spectra of plasma generated from the surface of sample of a green sandstone taken from King Sigismundus Chapel in Wawel castle in Cracow are presented. Using LlBS method (Laser Induced Breakdown Spectroscopy) a usefulness ot the Mechelle 900 - SensiCamFS system for chemical composition of investigated objects was proved.
PL
W pracy opisano tryb wyznaczania charakterystyk eksploatacyjnych spektrometru Mechelle 900 wyposażonego w kamerę SensiCamFS o czasie ekspozycji od 100 ns. Wyznaczono czułość widmową zestawu spektrometr-kamera oraz opracowano metodykę kalibracji radiometrycznej zestawu i wyznaczono krzywą kalibracji radiometrycznej. Zamieszczono przykładowe widma promieniowania plazmy laserowej wytworzonej z próbki zielonego piaskowca pobranego z Kaplicy Zygmuntowskiej na Wawelu w Krakowie. Stosując metodę LlBS (Laser Induced Breakdown Spectroscopy) wykazano przydatność zestawu Mechelie 900 SensiCamFS do wyznaczania składu chemicznego obiektów.
Rocznik
Strony
294--296
Opis fizyczny
Bibliogr. 9 poz., wykr.
Twórcy
  • Institute of Optoelectronics, Military University of Technology, Warsaw, Poland
  • Institute of Optoelectronics, Military University of Technology, Warsaw, Poland
Bibliografia
  • 1. http:/ / www.multichannel.se.
  • 2. Mechelle User's Manual, Multichannel lnstruments, 2003.
  • 3. S. Florek, C. Haisch, M. Okruss, H. Becker-Ross: A new, versatile echelle spectrometer relevant to laser induced plasma applications, Spectrochimica Acta, Part B, 56, pp. 1027-1034, 2001.
  • 4. V. Detalle, R. Heon, M. Sabsabi, L. St-Onge: An evaluation of a commercial Echelle spectrometer with intensified charge-coupled device detector for materials analysis by laser-induced plasma spectroscopy, Spectrochirmica Acta, Part B, 56, pp. 1011-1025, 2001.
  • 5. P. Lindblom: New compact Echelle spectrographs with multichannel time-resolved recarding capabilities Analytica Chimica Acta, 380, pp. 353-361, 1999.
  • 6. A. Uhl, K. Loebe, L. Kreuchwig: Fast analysis of wood preservers using laser induced breakdown spectroscopy Spectrochimica Acta, Part B, 56, pp. 795-806, 2001.
  • 7. C. Haisch, U. Panne, R. Niessner: Combination of an intensified charge coupled device with an echelle spectrograph for analysis of colloidal material by laser-induced plasma spectroscopy, Spectrochimica Acta, Part B, 53, pp. 1657-1667, 1998.
  • 8. H. E. Bauer, F. Leis, K. Niemax: Laser induced breakdown spectrometry with an echelle spectrometer and intensified charge coupled device detection, Spectrochimica Acta, Part B, 53, pp. 1815-1825, 1998.
  • 9. H. Becker-Ross, S. V. Florek: Echelle spectrometers and charge-coupled devices, Spectrochimica Acta, Part B, 52, pp. 1367-1375, 1997.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWA2-0013-0022
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.