PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The behaviour of the mechanical oscillator flowmeters under pulsating flow conditions

Autorzy
Identyfikatory
Warianty tytułu
PL
Zachowanie przepływomierza z oscylatorem mechanicznym w obecności pulsacji przepływu
Konferencja
International Conference Mechatronics 2004 (5 ; 23-25.09.2004 ; Warsaw, Poland)
Języki publikacji
EN
Abstrakty
EN
The influence of the flow rate pulsation on the characteristics of the mechanical oscillator flowmeters has been investigated. The phenomenon of the frequency "lock-in", well known from the vortex flowmeters, also occurs in the mechanical oscillator flow-meter. The results of the investgation showed that in the presence of pulsation the mechanical oscillator flowmeter can give false readings and the error can achieve the value of 27% at pulsation amplitude of 13%.
PL
Przedstawiono wyniki badań wpływu pulsacji na wskazania przepływomierzy z oscylatorem mechanicznym. Zjawisko unoszenia częstotliwości, znane z przepływomierzy wirowych, występuje także w przypadku przepływomierzy z oscylatorem mechanicznym. Z badań wynika, że w obecności pulsacji błędy przepływomierza mogą osiągnąć wartość do 27% przy amplitudzie pulsacji równej 13%.
Rocznik
Strony
254--256
Opis fizyczny
Bibliogr. 12 poz., wykr.
Twórcy
autor
  • Warsaw University of Technology, Faculty of Mechatronics, Institute of Metrology and Measuring Systems, Poland
Bibliografia
  • 1. Heckle, M.: Ein neues Durchflussmessvefahren mit Frequenzausgang. Messtechnik, 1971, 9, pp. 207-214.
  • 2. Lutz K.: Neue Wege in der Durchflussmessung. Erstmals nach dem Schwingkörpertechnik. Die Chemische Produktion. Jan./ Feb. 1977, pp. 7-9.
  • 3. Takahashi, S. ltoh I.: lntelligent vortex flowmeter. FLOMEKO'93, Proceedings of the 6th International Conference on Flow Measurement, Seoul, Korea, 1993, pp. 107-113.
  • 4. Miau J. J., Hu C. C., Chou J. H.: Response of a vortex flowmeter to impulsive vibrations. Flow measurement and lnstrumentation, 2000, 11 , pp. 41-48.
  • 5. Johnson A. : Applying vortex flow metering technology in demanding process applications. Proceedings of the Flow Measurement 2001 - International Conference, Peebles, Scotland, 2001, paper 4.4.
  • 6. Turkowski M.: Progress towards the optimisation of a mechanical oscillator flowmeter. Flow Measurement and Instrumentation, vol. 14, issues 1-2 March - April 2003, pp. 13-21.
  • 7. Turkowski M.: Influence of fluid properties on the characteristics of the flowmeter with mechanical oscillator. Measurement, 35/ 1 (2004), pp. 11-18.
  • 8. Hebrard P., Malard L. And Strzelecki A.: Experimental study of a vortex flowmeter in pulsatile flow conditions. Flow Measurement and Instrumentation, 1992, 3, 173-186.
  • 9. ISO CD TR 3313:1997: The effect of flow pulsation on flow measuring instruments: orifice plates, nozzles or venturi tubes, turbine and vortex flow meters.
  • 10. Dobrowolski B., Kabza Z., Pospolita J.: Theoretische und experimentalle untersuchungen des Einflusses des pulsationsstromung auf die Charakteristiken der Drosselgerate. VDI Verlag GmbH, Dusseldorf 1991.
  • 11. Carpinlioglu M. Ö., Gundogdu M. Y.: Presentation of a test system in terms of generated pulsatile flow characteristics. Flow Measurement and Instrumentation, 12 (2001 ), pp. 181-190.
  • 12. Carpinlioglu M. Ö, Gundogdu M. Y.: A critical review on pulsatile pipe flow studies directing towards future research topics. Flow Measurement and lnstrumentation, 12 (2001), pp. 181-190.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWA2-0013-0008
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.