PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Antenatal fetal surveillance using bioelectrical signals

Identyfikatory
Warianty tytułu
PL
Przedporodowy nadzór płodu poprzez rejestrację i analizę biosygnałów
Konferencja
International Conference Mechatronics 2004 (5 ; 23-25.09.2004 ; Warsaw, Poland)
Języki publikacji
EN
Abstrakty
EN
A new approach alternative to cardiotocographic conventional letal monitoring is presented. It relies upon analysis of bioelectrical signals recorded from maternal abdominal wall. Due to strong interferences present in abdominal signal advanced methods of signal processing have been developed to extract letal electrocardiogram and uterine electrical activity signal. The described system allows replacement of more expensive cardiotocographic instrumentation based on ultrasound. Doppler method and ensures the higher diagnostic capacity at the same time.
PL
W pracy przedstawione zostało nowe, alternatywne w stosunku do tradycyjnej kardiotokogralii, podejście do monitorowania stanu płodu w okresie przedporodowym. Zostało ono oparte o rejestrację i analizę biosygnałów rejestrowanych z powierzchni brzucha matki. Występujące w tych sygnałach zakłócenia wymagają stosowania zaawansowanych technik przetwarzania sygnałów w celu wydobycia użytecznej informacji: elektrokardiogramu płodu i sygnału elektrycznej aktywności mięśnia macicy. Opracowany został uniwersalny system do monitorowania płodu pozwalający zastąpić kosztowne aparaty kardiotokograliczne wykorzystujące technikę ultradźwiękową, a zapewniający przy tym znacznie większe możliwości oceny i detekcji stanu zagrożenia płodu.
Rocznik
Strony
110--113
Opis fizyczny
Bibliogr. 7 poz., wykr.
Twórcy
autor
  • Medical Technology and Equipment, Zabrze, Poland
autor
  • Medical Technology and Equipment, Zabrze, Poland
autor
  • Medical Technology and Equipment, Zabrze, Poland
autor
  • Medical Technology and Equipment, Zabrze, Poland
autor
  • Medical Technology and Equipment, Zabrze, Poland
Bibliografia
  • 1. Jeżewski J., Wróbel J., Horoba K., Cholewa O., Gacek A., Kupka T., Matonia A.: ,,Monitoring of mechanical and electrical activity of fetal heart: The nature of signals", Arch. of Perinat. Med., 2002, vol. 8, pp. 40-46.
  • 2. Jeżewski J., Wróbel J., Horoba K., Matonia A., Kupka T.: ,,Estimation of beat-to-beat accuracy of fetal heart rate data obtained via Doppler ultrasound", in IFMBE Proc. of 2nd European Med. & Biol. Eng. Conf. EMBEC, 2002, Vienna, pp. 1536-1537.
  • 3. Pieri J.F., Crowe J.A., Hayes-Gill B.R., Spencer C.J., Bhogal K., James D.K.: ,,Compact long-term recorder for the transabdominal foetal and maternal electrocardiogram", Med. Biol. Eng. Comput., 2001, vol 39, pp. 118-125.
  • 4. Bergveld P., Meijer W.J.H.: ,,A New Technique for the Suppression of the MECG", IEEE Trans. Biomed. Eng., 1981, vol. 28, pp. 348-354.
  • 5. Matonia A., Jeżewski J., Wróbel J., Horoba K., Kupka T.: ,,Application of spatial filtration in noninvasive fetal electrocardiography", in VI Int. Conf. SYMBIOSIS, 2001, Szczyrk, pp. 45-51.
  • 6. Horoba K., Jeżewski J., Wróbel J., Graczyk S.: ,,Algorithm for detection of uterine contractions from electrohysterogram", in: 23rd Int. Conf. of the IEEE EMBS, 2001, Istanbul, pp. 461-464.
  • 7. Rosen K.G.: ,,Intrapartum fetal monitoring and the fetal ECG - time for a change", Arch. of Perinat Med., 2001, vol. 7, pp. 7-12.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWA2-0011-0068
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.