PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Multichannel capacitance tomograph for dynamic process imaging

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Konferencja
The Fourth Scientific Symposium on Image Processing Technology. TPO 2002 ; (21.11-23.11.2002 ; Serock, Poland)
Języki publikacji
EN
Abstrakty
EN
The Division of Nuclear and Medical Electronics of Warsaw University of Technology is an institution where a capacitance process tomograph was first designed in Poland. The design of this capacitance tomograph, its performance and first results are presented in the paper. The tomograph can operate with one or two probes with up to 32 electrodes altogether. Twelve or sixteen electrode configurations is commonly used and a two times twelve or two times sixtheen electrode set up is provided for flowmeter applications. Additionally, the device has functionality of a 16-channel capacitance meter for industrial applications. The tomograph has a novel modular structure. It consists of 16 analogue signal cards, a motherboard and a control module with an analogue to digital converter. The measurement is based on a standard charge-discharge method. The signal card is capable to work both as a transmitter and a receiver during the measurement process. The motherboard provides communication between signal cards and the control module using a custom digital bus. The control module contains a 16-bit analogue to digital converter, a control logic, and a serial communication interface. All digital electronic circuits have been designed using programmable logic devices (PLDs).
Rocznik
Strony
175--180
Opis fizyczny
Bibliogr. 4 poz., fot., rys., wykr.
Twórcy
autor
  • Warsaw University of Technology, Division of Nuclear and Medical Electronics, 15/19 Nowowiejska Str., 00-665 Warsaw, Poland
autor
  • Warsaw University of Technology, Division of Nuclear and Medical Electronics, 15/19 Nowowiejska Str., 00-665 Warsaw, Poland
autor
  • Warsaw University of Technology, Division of Nuclear and Medical Electronics, 15/19 Nowowiejska Str., 00-665 Warsaw, Poland
  • Industrial Institute of Organie Chemistry, 6 Annopol Str., 03-236 Warsaw, Poland
autor
  • Warsaw University of Technology, Division of Nuclear and Medical Electronics, 15/19 Nowowiejska Str., 00-665 Warsaw, Poland
autor
  • Warsaw University of Technology, Division of Nuclear and Medical Electronics, 15/19 Nowowiejska Str., 00-665 Warsaw, Poland
Bibliografia
  • 1. P. Brzeski, "Tomographic techniques and image processing for process tomography. Research activities", Proc. Symp. Process Tomography, Jurata, May 18-19, 2000.
  • 2. T. Olszewski, "Capacitance tomograph - design and preliminary results", Proc. 2 nd Int. Symp. on Process Tomography in Poland, Wrocław, pp. 159-168 (2002).
  • 3. W.Q. Yang, "Hardware design of electrical capacitance tomography systems", Meas. Sci. Technol. 7, 225-232 (1996).
  • 4. N. Reinecke and D. Mewes, "Recent developments and industrial/research applications of capacitance tomography", Meas. Sci. Technol. 7, 233-246 (1996).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWA2-0007-0035
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.