Electrocatalytic sensor based on Nasicon with auxiliary layer

Identyfikatory
Warianty tytułu
PL
Czujnik elektrokatalityczny na bazie Nasiconu z warstwą dodatkową
Konferencja
35th International Microelectronics and Packaging IMAPS - IEEE CPMT Poland Conference ; 21-24.09. 2011 ; Gdańsk Sobieszewo, Poland
Języki publikacji
EN
Abstrakty
EN
In this study properties of Nasicon solid state gas sensors working in electrocatalytic mode are investigated. The principle of operation of such sensors is based on the excitation with a periodic potential signal, while current response is recorded. The sensors are prepared in ceramic technology with two different constructions. One construction is a symmetrical, sandwich type structure with electrolyte between two identical gold electrodes. In the second, the same structure is used, but the electrodes are covered with auxiliary layer of sodium nitrite. Nitrogen dioxide sensing properties of both sensors are determined and compared.
PL
W pracy zostały przedstawione wyniki pomiarów czujnika na bazie Nasiconu pracującego w trybie elektrokatalitycznym. Czujniki takie pobudzane są zmieniającym się napięciem przy jednoczesnym pomiarze odpowiedzi prądowej. Przygotowano czujniki ceramiczne o dwóch różnych typach. Pierwszy z nich to czujnik posiadający dwie identyczne elektrody złote, pomiędzy którymi znajduje się elektrolit stały. Drugi czujnik posiada złote elektrody dodatkowo pokryte warstwą azotanu (III) sodu. Zmierzono i porównano odpowiedzi obu czujników dla różnych stężeń dwutlenku azotu w mieszaninie z powietrzem.
Rocznik
Strony
72--74
Opis fizyczny
Bibliogr. 10 poz., wykr.
Twórcy
autor
autor
  • Gdańsk University of Technology, Department of Chemical and Process Engineering
Bibliografia
  • [1] Yang Y., Liu C.-C.: Development of a NASICON-based amperometric carbon dioxide sensor. Sensors and Actuators B, Vol. 62, Issue 1, 2000, pp. 30-34.
  • [2] Yamazoe N., Hosohara S., Fukada T., Isono K., Miura N.: Gas sensing interfaces of solid electrolyte based carbon dioxide sensors attached with metal carbonate. Sensors and Actuators B, Vol. 34, Issues 1-3, 1996, pp. 361-366.
  • [3] Jasiński G., Jasiński P., Chachulski B., Nowakowski A.: Electrocatalytic gas sensors based on Nasion and Lisicon. Materials Science- Poland, Vol. 24, No. 1, 2006, pp. 261-268.
  • [4] Jasiński G., Jasiński P., Nowakowski A., Chachulski B.: The influence of electrocatalylic toxic gas sensor construction on its performance. Proceedings of 31th International Conference of IMAPS-Poland, Rzeszów-Krasiczyn, 2007, pp. 343-346.
  • [5] Miura N., Lio M., Lu G., Yamazoe N.: Solid-state amperometric NO2 sensor using a sodium ion conductor. Sensors and Actuators B, Vol. 35, Issues 1-3, 1996, pp. 124-129.
  • [6] Miura N., Ono M., Shimanoe K., Yamazoe N.: A compact solid-state amperometric sensor for detection of NO2 in ppb range. Sensors and Actuators B, Vol. 49, Issues 1-2, 1998, pp. 101-109.
  • [7] Choi S.-D., Chung W.-Y., Lee D.-D.: SO2 sensing characteristics of Nasicon electrolytes. Sensors and Actuators B, Vol. 36, Issues 1-3, 1996, pp. 263-266.
  • [8] Weppner W.: Solid state electrochemical gas sensors. Proc. 2nd Int. Meeting on Chemical Sensors, Bordeaux, 1986, pp. 59-68.
  • [9] Quon D. H. H., Wheat T. A., Nesbitt W.: Synthesis, characterization and fabrication of Na1+x Zr2 Six P3-x O12, Materials Research Bulletin. Vol. 15, Issue 11, 1980, pp. 1533-1539.
  • [10] Strzelczyk A.: Sensitivity to nitrogen dioxide of electrocatalytic gas sensor based on NASICON, 14th International Symposium of Students and Young Mechanical Engineers „Advances in Chemical and Mechanical Engineering”, Vol. 2/2, 5th -7th may 2011, Gdańsk, 2011, 250-256.