Modeling of Synchronous Data Streams Processing in the RPC Muon Trigger System of the CMS Experiment

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper presents signal synchronization aspects in a large, distributed, multichannel RPC Muon Trigger system in the CMS experiment. The paper is an introduction to normalized structure analysis methods of such systems. The method introduces a general model of the system, presented in a form of a network of distributed, synchronous, pipeline processes. The model is based on a definition of a synchronous data stream and its formal, fundamental properties. Theoretical considerations are supported by a practical application of synchronous streams and processes management. The following processes were modeled and implemented in hardware: window synchronization, derandomization, data concentration and generation of test pulses. There are presented chosen results of the model application in the CMS experiment.
Twórcy
Bibliografia
  • [1] M. Felcini, “The trigger system of the CMS experiment,” Nucl. Instr. And Meth. A, vol. 598, no. 1, pp. 312-316, 2009.
  • [2] S. Chatrchyan et al., “The CMS experiment at the CERN,” Journal of Instrumentation, vol. 3, no. S08004, 2008.
  • [3] M. Abbrescia et al., “The RPC system for the CMS experiment at the LHC,” Nucl. Instr. and Meth. A, vol. 508, pp. 137-141, 2003.
  • [4] M. Górski, M. Kudla, and K. T. Poźniak, “Resistive plate chamber (RPC) based muon trigger system for the CMS experiment data compression/decompression system,” Nucl. Instr. and Meth. A, vol. 419, pp. 701-706, 1998.
  • [5] K. Bunkowski et al., “Synchronization methods for the PAC RPC trigger system in the CMS experiment,” Measurement Science and Technology, Institute of Physics, London, vol. 18, pp. 2446-2455, 2007.
  • [6] K. Bunkowski, “Optimization, synchronization, calibration and diagnostic of the RPC PAC muon trigger system for the CMS detector,” Ph.D. dissertation, Institute of Experimental Physics, University of Warsaw, 2009.
  • [7] R. T. Rajan et al., “A configurable tracking algorithm to detect cosmic muon tracks for the CMS-RPC based technical trigger,” Nucl. Instr. And Meth. A, vol. 602, pp. 792-795, 2009.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWA0-0046-0041
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.