Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
XXI century will be period of the fast progress of biological and medical sciences. It is result of technical sciences evolution and evolution of biomechanics like a science combinated both areas. The period of the people's living will be longer and this is connected with new constructions for implantation and rehabilitation. The paper presents some problems and discution about new directions in biomechanics connected with external osteosynthesis and gait analysis with exoskeletons.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
33--50
Opis fizyczny
Bibliogr. 17 poz., fot., il., wykr.
Twórcy
autor
- Faculty of Mechatronics, Warsaw University of Technology, danuta@mchtr.pw.edu.pl
Bibliografia
- 1. Brighton, C.T., 1984, Principles of Fracture Healing, Part I, The Biology of Fracture Repair, Instr. Course Lect,.
- 2. Jasińska-Choromańska, D., 2001, Mathematical Modelling and Simulation in the Design of the Unilateral Externa Orthopaedic Fixators, sciences works Vol. Mechanics, No 186, p. 109, Warsaw.
- 3. Jasińska-Choromańska, D., 2001, Problems of modelling and computer simulation of mechatronic orthopaedic external fixators, 10th Intern. Conf. SMC (System-Modelling- Control), Zakopane, 333-338.
- 4. Jasińska-Choromańska, D., Kabziński, B., 2004, Methods for analyzing human motion functions, Electronics, No 8-9, SIGMA, Warsaw.
- 5. Jasińska-Choromańska, D., Kabziński, B., 2005, Method for Gait Aiding and Analysis, 3rd European Medical and Biological Engineering Conference - EMBEC ’05, Czechy Rep., CD.
- 6. Jasińska-Choromańska, D., Kołodziej, D., 2003, Microdrives in active dynamizations of the fixators, Proceedings of International Conference Mechatronics, Robotics and Biomechanics, Hrotovice, Czech Republic, CD.
- 7. Jasińska-Choromańska, D., Korzeniowski, D., 2004, Analysis of gait diagnostics for people with implants, Engineering Mechanics, 12, No 5, Czech Rep.
- 8. Jasińska-Choromańska, D., Korzeniowski, D., 2005, Gait Diagnostics Devices for People with Implants, 3rd European Medical and Biological Engineering Conference - EMBEC’05, Czech Rep., CD.
- 9. Jasińska-Choromańska, D., Pawlicki, G., Deszczyński, J., Karpiński, J., Choromanski, W., 1996, Motion And Vibration Control In Medicine - Focus On New Generation of Orthopaedic External Fixator, The Third International Conference on Motion and Vibration Control MOVIC, Tokio, II, 381-386.
- 10. Jasińska-Choromańska, D., Potyński, A., Kołodziej, D., 2002, Orthopaedic frame for unloading of limb fractures, sciences works of UTP, z. 54, 115-120, Wyd. Polit. Pozn., Poznań.
- 11. Jasińska-Choromańska, D., Sadzyński, I., 2003, Young modulus changes during healing of fractures of long bones, Proceedings of International Conference Mechatronics, Robotics and Biomechanics, Hrotovice, Czech Republic, CD.
- 12. Kołodziej, D., Jasińska-Choromańska, D., 2005, Special Kinds of Diagnosis in the External Osteosynthesis, 3rd European Medical and Biological Engineering Conference - EMBEC’05, Czech Rep., CD.
- 13. Levitt, S., 2000, Rehabilitation In cerebral palsy and movement impairment, PZWL Warsaw.
- 14. Marciniak, W., Szulc, A., 2003, Wiktor Dega orthopedic and rehabilitation., PZWL, Warsaw.
- 15. Nałęcz, M. and others, 2004, Biocybernetics end Biomedical Engineering, PAN Warsaw.
- 16. Perry, J., 1992, Gait Analysis. Normal and Pathological Function, Slack Incorporated.
- 17. Yager, R.R., FiIe,VD.P., 1995, Fundamentals on Fuzzy Modelling and Control, Warsaw, WNT.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BWA0-0006-0078