Acoustics of Classrooms in Primary Schools - Results of the Reverberation Time and the Speech Transmission Index Assessments in Selected Buildings

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The article presents results of our own research regarding acoustic properties of 110 classrooms in five typical primary schools in Warsaw. The target of the re- search was to assess the classrooms using established criteria. These criteria include the reverberation time and the speech transmission index. The research has shown a large diversity of acoustic properties of classrooms within each of the schools and between the schools, resulting from the classroom equipment and the school building construction. In addition, the assessment has indicated that classrooms in schools researched do not meet the established acoustic criteria (reverberation time and speech transmission index). Because the classroom equipment is different for younger forms (integrated teaching) and for older forms (subject teaching), the results have been analyzed separately for rooms for younger forms (0–III) and for rooms for older forms (IV–VI). Synthetic results prove the advisability of such di- vision. Correlation analysis has been conducted for the speech transmission index STI and reverberation time Tmf , as well as for the speech transmission index STI and the suggested reverberation time Twf defined in a similar manner as Tmf , but in a wider frequency range. The correlation between the speech transmission index STI and Twf is higher than that between the STI index and Tmf . The reverberation time Twf can therefore be used for a more precise assessment of acoustic properties of interiors with regard to verbal communication than Tmf . In addition, the paper presents estimated analysis results of the influence of selected classroom equipment (carpets) on its acoustic properties.
Rocznik
Strony
777--793
Opis fizyczny
Bibliogr. 15 poz., tab., wykr.
Twórcy
autor
autor
  • Central Institute for Labour Protection– National Research Institute Czerniakowska 16, 00-701 Warszawa, Poland, wimik@ciop.pl
Bibliografia
  • 1. Augustyńska D., Kaczmarska A., Mikulski W., Radosz J. (2010), Assessment of teachers' exposure to noise in primary schools, Archives of Acoustics, 35, 4, 521-542.
  • 2. Bradley J.S., Sato H. (2008), The intelligibility of speech in elementary school class-rooms, Journal of Acoustical Society of America, 123, 4, 2078-2086.
  • 3. Engel Z., Engel J., Kosała K., Sadowski J. (2007), Basics of sacral objects acoustics [in Polish: Podstawy akustyki obiektów sakralnych], WITE-PIB, Kraków-Radom.
  • 4. Koszarny Z., Chyla A. (2003), School rooms' acoustic characteristics [in Polish: Właściwości akustyczne pomieszczeń szkolnych], Rocznik PZH, 3, 311-320.
  • 5. Kotus J., Szczodrak M., Czyżewski A., Kostek B. (2010), Long-term comparative evaluation of acoustic climate in selected schools before and after acoustic treatment, Archives of Acoustics, 35, 4, 551-564.
  • 6. Mikulski W., Radosz J. (2009), Acoustic properties of classrooms in elementary schools, Proceedings of 56th Open Seminar on Acoustics, Warszawa-Goniądz, 57-62.
  • 7. Mikulski W., Radosz J. (2010), The influence of volume and use of classrooms in elementary schools on the acoustic properties [in Polish: Wpływ objętości i wyposażenia na właściwości akustyczne sal lekcyjnych], Proceedings of 15th International Conference on Noise Control, Książ-Wałbrzych.
  • 8. Radosz J., Mikulski W. (2011), Experimental comparison between sound sources with different directivity in investigating acoustic properties of selected classrooms in elementary schools, Proceedings of Inter Noise 2011, Osaka, Japan.
  • 9. Rudno-Rudzińska B., Czajkowska K. (2010), Analysis of acoustic environment on premises of nursery schools in Wrocław, Archives of Acoustics, 35, 2, 245-252.
  • 10. Sato H., Bradley J.S. (2008), Evaluation of acoustical conditions for speech communication in working elementary school classrooms, Journal of Acoustical Society of America, 123, 4, 2064-2077.
  • 11. EN ISO 3382-2:2008. Acoustics. Measurements of room acoustics parameters. Part 2: Reverberation time in ordinary rooms (ISO 3382-2:2008).
  • 12. SFS 5907:en Acoustics classification of spaces in buildings.
  • 13. prPN-B-02151-4, supersedesPN-87/B-02151.02 Building acoustics. Noise protection of apartments in buildings. Permissible values of sound level [in Polish: Akustyka budowlana. Ochrona przed hałasem pomieszczeń w budynkach. Dopuszczalne wartości poziomu dźwięku w pomieszczeniach].
  • 14. Technical requirements to be met by buildings and their location [in Polish: Warunki techniczne jakim powinny odpowiadać budynki i ich usytuowanie - Tekst ujednolicony po nowelizacji z komentarzem], Instytut Techniki Budowlanej, Warszawa 2009.
  • 15. Building Bulletin 93 (2003) - School Acoustics.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUS8-0020-0046
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.