Toxicity assessment of hospital wastewater by the use of a biotest battery

Identyfikatory
Warianty tytułu
PL
Zastosowanie baterii biotestów do oceny toksyczności ścieków szpitalnych
Języki publikacji
EN
Abstrakty
EN
In the paper toxicity assessment of hospital wastewaters samples was performed using direct-contact tests consisting of five species, which represent three different trophic levels of the food chain. IC_50 or EC_50 values were estimated for each tested organism: Pseudokirchneriella subcapitata IC_50/72h 18.77%, Daphnia magna EC_50/48h 20.76%, Thamnocephalus platyurus EC_50/24h 22.62%, Artemia salina EC_50/24h 59.87% and Vibrio fisheri EC_50/15min 46.17%. Toxic potential of hospital wastewater was described using a system of wastewater toxicity classification. The toxic units (TU) values estimated for each test indicate that hospital wastewaters are toxic (Class III). The variable results of the tests' sensitivity confirmed the need of application of microbiotests battery with organisms of different trophic levels.
PL
Do oceny potencjału toksykologicznego ścieków szpitalnych zastosowano baterię biotestów z wykorzystaniem pięciu gatunków reprezentujących trzy różne poziomy troficzne. Wartości wskaźników ekotoksykologicznych wyznaczone w poszczególnych testach wyniosły: test inhibicji wzrostu glonów Pseudokirchneriella subcapitata IC_50/72h 18,77%, testy toksyczności ostrej z wykorzystaniem skorupiaków Daphnia magna EC_50/48h 20,76%, Thamnocephalus platyurus EC_50/24h 22,62%, Artemia salina EC_50/24h 59,87% oraz test toksyczności chronicznej z wykorzystaniem bakterii morskich Vibrio fischeri EC_50/15min 46,17%. Dla każdego testu obliczono jednostki toksyczności TU, na podstawie których analizowane próby ścieków szpitalnych zaklasyfikowano jako toksyczne. Szeroki zakres otrzymanych wartości wskaźników ekotoksykologicznych wyznaczonych dla poszczególnych organizmów testowych, potwierdza konieczność stosowania rozbudowanej pod względem różnorodności organizmów baterii biotestów.
Rocznik
Strony
55--61
Opis fizyczny
Bibliogr. 13 poz., tab., wykr.
Twórcy
autor
Bibliografia
  • [1] Azur Environmental: Microtox Standard Operational Procedure, (1991).
  • [2] Berto J., G.C. Rochenbach, M.A.B. Barreiros, A.X.R. Correa, S. Peluso-Silva, C.M. Radetski: Physicochemical, microbiological and ecotoxicological evaluation of septic tank/Fenton reaction combination for the treatment of hospital wastewaters, Ecotoxicology and Environmental Safety, 72, 1076−1081 (2009).
  • [3] Escher B.I., R. Baumgartner, M. Koller, K. Treyer, J. Lienert, Ch.S. McArdell: Environmental toxicology and risk assessment of pharmaceuticals from hospital wastewater, Water Research, 30, 1−18 (2010).
  • [4] ISO 6341:1996 Water Quality, Determination of the inhibition of the mobility Daphnia magna Straus (Cladocera, Crustacea), Acute toxicity test.
  • [5] Kummerer K.: Drugs in the environment: emission of drugs, diagnostic aids and disinfectants into wastewaters by hospital in relation to other sources-a review, Chemosphere, 45, 957-969 (2001).
  • [6] Langford K. H., K. V. Thomas: Determination of pharmaceutical compounds in hospital effluents and their contribution to wastewater treatment works, Environmental International, 35, 766-770 (2009).
  • [7] Microbiotest: Artotoxkit Standard Operational Procedure (1996).
  • [8] Microbiotest: Thamnotoxkit Standard Operational Procedure (1998).
  • [9] OECD 201 Guideline for testing of chemicals, Algal Growth Inhibition test (1984).
  • [10] Onesios K.M., J.T. Yu, E.J. Bouwer: Biodegradation and removal of pharmaceuticals and personal care products in treatment systems: a review, Biodegradation, 20, 441-446 (2009).
  • [11] Persoone G., B. Marsalek, I. Blinova, A. Torkokne, D. Zarina, L. Manusadzianas, G. Nalecz-Jawecki, L. Tofan, N. Stepanova, L. Tothova, B. Kolar: A practical and user-friendly toxicity classification system with microbiotests for natural waters and wastewaters, Environmental Toxicology, 18, 395-402 (2003).
  • [12] Verlicchi P., A. Galletti, M. Petovic, D. Barcelo: Hospital effluents as a source of emerging pollutants: An overview of micropollutants and sustainable treatment options, Journal of Hydrology 389, 416-428 (2010).
  • [13] Wojnicz M., A.M. Anielak: Kinetics of dairy wastewater treatment in the SBR system, Archives of Environmental Protection, 36, 27−37 (2010).