Use of microwave-assisted digestion for determination of element contents in environmental materials by ICP-AES and FAAS

Autorzy
Identyfikatory
Warianty tytułu
PL
Zastosowanie mineralizacji mikrofalowej do określenia zawartości śladów w próbkach środowiskowych metodami ICP-AES i FAAS
Języki publikacji
EN
Abstrakty
EN
The methods arc described for determinations of Al, Fe, Ca, Mg, Ba, Cr, Mn, Ni, Cu, Zn, Pb, Cd, V and Sr in botanical, coal fly ash and soil samples by flame atomic absorption spectrometry (FAAS), and inductively coupled plasma atomic emission spectrometry (ICP-AES). Special attention has been paid to sample preparation, an important stage at which a sample is explored to contaminants. Results of the analysis of all samples arc discussed.
PL
Zaproponowano metody oznaczania: Al, Fe, Ca, Mg, Ba, Cr, Mn, Ni, Cu, Zn, Pb, Cd, V i Sr w próbkach roślinnych, popiołu lotnego i gleby metodami absorpcyjnej spektrometrii atomowej w technice płomieniowej (FAAS) i atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie indukcyjnie sprzężonej (ICP-AES). Szczególną uwagę zwrócono na przygotowanie próbek, roztwarzanie, będące niezwykle ważnym i istotnym krokiem, w którym próbka narażona jest na zanieczyszczenie. Otrzymane wyniki posłużyły do przeprowadzenia dyskusji na temat roztwarzania i mineralizacji analizowanych materiałów.
Rocznik
Strony
89--104
Opis fizyczny
tab., bibliogr. 41 poz.
Twórcy
autor
  • Institute for Chemical Processing of Coal 111. Zamkowa 1, 41-803 Gliwice, Poland
Bibliografia
  • [1] Abu-Samara A., J.S. Morris, S.R. Koirtyohann: Wet ashing of some biological samples in a microwave oven, Anal. Chem., 47, 1475-1477 (1975).
  • [2] Bettinelli M, U. Baroni, N. Pastorelli: Microwave oven sample dissolution for the analysis of environmental and biological materials. Anal. Chim. Acta, 225, 159-174 (1989).
  • [3] Bettinelli M., U. Baroni, N. Pastorelli: Determination of arsenic, cadmium, lead, antimony, selenium and thallium in coal fly ash using the stabilized temperature platform furnace and Zeeman-effect background correction, J. Anal. Atom. Spectrom., 3, 1005-1011 (1988).
  • [4] Capota P., G.E. Baiulescu, M. Constantin: The analysis of environmental samples by ICP-AES, Chem. Anal. (Warsaw), 41, 419-427 (1996).
  • [5] Carrion N., Z.A. de Benzo, B. Moreno, A. Fernandez, J.E. Eljuri, D. Flores: Determination of copper, chromium, iron and lead in pine needles by electrothermal atomic absorption spectrometry with slurry sample introduction, J. Anal. Atom. Spectrom., 3, 479-483 (1988).
  • [6] Fagioli F., S. Landi, C. Locatelli, C. Bighi: Determination of lead and cadmium in small amounts of biological material by graphite furnace atomic absorption spectroscopy with sampling of carbonaceous slurry, At. Spectrosc., 7, 49-51 (1986).
  • [7] Galas W., A. Kita: Determination of ten elements in the spice samples using an inductively coupled plasma-atomic emission spectroscopy, Chem. Anal. (Warsaw), 42, 403-409 (1997).
  • [8] Hoenig M., A.M. dc Kersabicc: Sample preparation steps for analysis by atomic spectroscopy methods present status, Spcctrochim. Acta, SIB, 1297-1307 (1996).
  • [9] Stern E.A., Heald S.M.: Basic principles and applications of EXAFS, [in:] Koch E.E. (Ed.): Handbook on Synchrotron Radiation, North-Holland, Amsterdam (1983) Chapter 10, vol. 1, pp. 957-1014.
  • [10] Hyk W., Z. Stojek: Analysis of statistic in the laboratory, Committee of Analytical Chemistry PAN, Warsaw 2000.
  • [11] Kingston K.M., L.B. Jassic: Introduction to Microwave Sample Preparation, American Chemical Society, Washington DC, 1988.
  • [12] Karadjova I., M. Karadjov: ETAAS determination of Cd and Pb in plants, Frcscnius J. Anal. Chem., 340, 246-251 (1998).
  • [13] Krolak E.: Accumulation of Zn, Cu, Pb and Cd by Dandelion (Taraxacum officinale Web.) in environments with various degrees of metallic contamination, Polish J. Environ. Stud., 6, 713-721 (2003).
  • [14] Kubrakova I.: Microwave-assisted sample preparation and preconcentration for ETAAS, Spectrochim. Acta, 52 B, 1469-1481 (1997).
  • [15] Lachas H., R. Richaud, K.E. Jarvis, A.A. Herod, D.R. Dugwcll, R. Kandiyoti: Determination of 17 trace elements in cola and ash reference materials by ICP-MS applied to milligram sample sizes, Analyst, 124, 177-184 (1999).
  • [16] Laitinen T, H. Revitzer, M. Tolvanen: Trace metal analysis of coal fly ash collected plain and on a quartz fiber filter, Fresenius J. Anal. Chem., 354, 436-441 (1996).
  • [17] Lippo H., A. Sarkela: Microwave dissolution method for the determination of heavy metals in biomonitors using GFAAS and Flame AAS, Atom. Spectrosc.. July/August, 154-157 (1995).
  • [18] Sargent M., Webb K.: Instrumental aspects of inductively coupled plasma-mass spectrometry, Spectrosc. Europe, 5, 21-28 (1993).
  • [19] Lopez-Garcia I., N. Campillo, I. Arnau-Jerez, M. Hernandez-Cordoba: Slurry sampling for the determination of silver and gold in soils and sediments using electrothermal atomic absorption spectrometry, Spectrochim. Acta, 58B, 1715-1721 (2003).
  • [20] Manual of the Milestone Microwave Digestion System, Model MLS-1200 MEGA, Soristole, Italy.
  • [21] Park C.J., Hall G.E.M.: Analysis of biological materials by inductively coupled plasma mass spectrometry with sample introduction by electrothermal vaporization. Part I. Determination of molybdenum and tungsten, J. Anal. At. Spectrom., 2, 473-480 (1987).
  • [22] Matusiewicz H., R.E. Sturgeon: Present status of microwave sample dissolution and decomposition for elemental analysis, Prog. Anal. Spectrosc., 12, 12-39 (1989).
  • [23] Mingorance M.D., M.L. Perez-Vazquez, M. Lachica: Microwave digestion methods for the atomic spectrometric determination of some elements in biological samples, J. Anal. Atom. Spectom., 8, 853-858 (1993).
  • [24] Nerin C., J. Casado, J. Cacho: Mineral speciation of copper and zinc in flying ash from a thermal power plant, Fresenius J. Anal. Chem., 337, 359-361 (1990).
  • [25] Nieuwenhuize J., C.H. Poley-Vos: A rapid microwave dissolution method for the determination of trace elements in lyophilized plant material, At. Spectrosc., 10, 148-153 (1989).
  • [26] Opydo J.: Voltammetric analysis of biological samples and soil after wet digestion using microwave irradiation, Chem. Anal. (Warsaw), 42, 123-127 (1997).
  • [27] Papp C.S.E., L.B. Fischer: Application of microwave digestion to the analysis of peat, Analyst, 112, 337-338 (1987).
  • [28] Plazmatronika Microwave System, Model Standard BM-1S/2, Wrocław Poland.
  • [29] Dziennik Ustaw nr 9, poz. 72, zał. 4, Warsaw 05.02.2001.
  • [30] Samczyński Z., R. Dybczyński: Ion exchange behavior of cadmium on amphoteric ion exchange resin Retardion HAS and its application for the determination of cadmium in biological materials by neutron activation analysis, Chem. Anal. (Warsaw), 41, 873 (1996).
  • [31] Schlemmer G., B. Welz: Determination of heavy metals in environmental reference materials using solid sampling graphite furnace AAS, Fresenius Z. Anal. Chem., 328, 405-409 (1987).
  • [32] Siebert A., I. Bruns, G.J. Krauss, J. Miersch, B. Markert: The use of the aquatic moss Fontinalis antipyretica L. ex Hedw. as a bioindicator for heavy metals, Sci. Total Environ., 177, 137-144 (1996).
  • [33] Smeda A., W. Zyrnicki: Application of sequential extraction and the ICP-AES method for study of the partitioning of metals in fly ashes, Microchcm. J., 72, 9-16 (2002).
  • [34] Stryjewska E., S. Rubel, I. Szykarczuk: Microwave digestion of biological material for vollammetric trace element analysis, Fresenius J. Anal. Chem., 354, 128-130 (1996).
  • [35] Stryjewska E., B. Krasnodębska, H. Biała, J. Teperek, S. Rubel: Heavy metal determination in moss samples from the Kampinos National Park, Chem. Anal. (Warsaw), 39, 483-490 (1994).
  • [36] Ribeiro A.S., M.A. Vieira, A.J. Curtius: Determination of hydride forming elements (As, Sb, Se, Sn) and Hg in environmental reference materials as acid slurries by on-line hydride generation inductively coupled plasma mass spectrometry, Spectrochim. Acta, 59B, 243-253 (2004).
  • [37] Richaud R., H. Lachas, M.-J. Lazaro., L.J. Clarke, K..E. Jarvis., A.A. Herod, T.C. Gibb, R. Kandioyoti: Trace element in coal derived liquids: analysis by ICP-MS and Mossbauer spectroscopy, Fuel, 79, 57-67 (2000).
  • [38] Terelak H., T. Motowicka-Terelak, T. Stuczyński, C. Pietruch, Trace element (Cd, Cu, Ni, Pb, Zn) in agricultural soils of Poland, Biblioteka Monitoringu Środowiska, Inspekcja Ochrony Środowiska, Warsaw 2000.
  • [39] Torigai M., T. Ouyang, K. Iwashima, M. Osako, M. Tanaka: Studies on microwave digestion procedures for the simultaneous multielement determination of arsenic, antimony, chromium, cadmium, nickel, and lead in municipal waste incineration fly ash by ICP-AES, Bunseki Kagaku, 46, 401-406 (1997).
  • [40] Vassileva E., H. Doiekalova, H. Baeten, S. Vanhentenrijk, M. Hoeing: Revisitation of mineralization modes for arsenic and selenium determinations in environmental samples, Talanta, 54, 187-196 (2001).
  • [41] Zunk B.: Mikrowellenaufschluss zur Bestimmung von Spurenelementen in Pflanzenmaterial, Anal. Chim. Acta, 236, 337-343 (1990).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUS2-0009-0090
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.