PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Indoor environment in buildings with natural ventilation

Autorzy
Identyfikatory
Warianty tytułu
PL
Środowisko wewnętrzne w budynkach z wentylacją naturalną
Języki publikacji
EN
Abstrakty
EN
The most important criteria for evaluation of building engineering is the state of indoor climate and energy consumption. Increase of the rate of energy saving resulted not only in the use of better barriers, but also building elements, such as windows, having low air leakage values. Simultaneously, in the design of new buildings and the retrofit of existing buildings, traditional structures of natural ventilation are used. In these cases, the ventilation is an important tool for a desiderable realization of all environmental and energy requirements. The paper presents selected results of a long-term research work. These results were obtained by questionnaires, measurements and simulations of ventilation processes in typical detached houses, blocks of flats and office buildings. The main objective of the presented paper is to demonstrate investigations and summarize a large number of results which describe the airtightness and natural ventilation on indoor environment.
PL
Jednymi z najważniejszych kryteriów dla oceny budynków jest stan klimatu wewnętrznego i zużycie energii. Silne tendencje do oszczędzania energii skutkują nie tylko stosowaniem lepszych przegród, ale również elementów budowlanych, takich jak okna, charakteryzujących się dużą szczelnością. Jednocześnie, w budynkach nowych oraz istniejących i modernizowanych, stosowane są tradycyjne rozwiązania wentylacji. W takich przypadkach działanie wentylacji staje się istotnym czynnikiem dla realizacji wymagań energetycznych i środowiskowych. Poniżej przedstawiono wybrane wyniki wieloletnich badań. Wyniki te uzyskano drogą badań ankietowych, kompleksowych pomiarów w jednorodzinnych, wielorodzinnych i biurowych budynkach istniejących oraz symulacji komputerowej procesów wentylacyjnych. Celem opracowania jest zaprezentowanie i podsumowanie dużej liczby badań opisujących wpływ wentylacji naturalnej i szczelności przegród na stan środowiska wewnętrznego.
Rocznik
Strony
3--22
Opis fizyczny
rys., tab., wykr., bibliogr. 21 poz.
Twórcy
autor
  • Silesian Technical University, Faculty of Environmental and Energy Engineering 111. Konarskiego 20, 44-100 Gliwice, Poland
Bibliografia
  • [1] Barabasz W., D. Albiriska: The occurrences and mycological threat of health in buildings, [in:] Proceedings of Symposium on Health and Gas Equipment, Krakow 2003, 47-56.
  • [2] Blucssyn P.M., C. Cox: Indoor environment quality and upgrading of European office buildings, Energy and Buildings, 34, 155-162 (2000).
  • [3] Carlsson P. et all.: Airtightness in Buildings, Swedish Building Research Publishing, D37, Informationprojckt AB, Stockholm 1980.
  • [4] Fanger P.O.: Indoor air quality in the 2 century. Indoor Air, 10, 68-73, (2000).
  • [5] Kukkoncn E. ct all.: Indoor Climate ~ Investigation and remedial measures, Nordtcst Finland TN-Rcport 294, Helsinki 1993.
  • [6] Liddament M.W.: A Guide to Energy Efficient Ventilation, Air Infiltration & Ventilation Centre, Coventry/Berkshire 1996
  • [7] Lubina P.: Investigation of a dynamic heat balances in rooms with internal heat gains, Ph.D. Thesis, Silesian Technical University, Gliwice 2004.
  • [8] Misniakiewicz E.: Impact of air exchange on indoor air quality, Ph.D. Thesis, Technical University of Opole, 2002.
  • [9] Nantka M.B.: Air Infiltration and Ventilation in Relation to the Thermal Performance of Dwelling Houses, Building Services Engineering, Research and Technology, London 1986, 7, 1, 11-19 (1986).
  • [10] Nantka M.B.: Airtightness and Natural Ventilation: A Case Study in Poland, The International Journal of Ventilation (London), 4, 1, 79-93, (2005).
  • [11] Nantka M.B.: A Method for Prediction of Air Flows in Multizone Buildings, Archives of Civil Engineering, Polish Scientific Academy, XLII, Warsaw, 2, 237-267 (1996).
  • [12] Nantka M.B.: Indoor Air Quality and Health Hazard in Dwellings with Natural Ventilation and Gas Appliances, [in:] Proceedings of III International Conference on Energy and Gas, Polish Academy of Science, Szczyrk 2005, 105-123.
  • [13] Nantka M.B.: New Concepts Aimed to Improve the Multizone Mode for Predicting Air Flows in the Building, [in:] Proceedings of International Congress on Indoor Air, Helsinki 1993, 5, 563-569.
  • [14] Oparczyk G.: Measurements of contaminants in indoor atmosphere for dwelling houses and office buildings, Ph.D. Thesis, Silesian Technical University, Gliwicc 2002.
  • [15] Pach J., A. Hubalewska-Hoida, D. Pach: Scintigraphic detection of cardiac injury of acutely carbon monoxide poisoned patients, Journal of Toxicol. Clin. Toxicol., 522 (2001).
  • [16] Persily A.K.: Carbon Monoxide Dispersion in Residential Buildings, National Institute of Standards and Technology Report no. 5906, USA 1996
  • [17] Roulet C-A.: How could investigations help in solving IAQ Problems, [in:] Proceedings of International Scientific Conference on Problems of Indoor Air Quality, Warsaw 1993, 71-77.
  • [18] Walton G.N.: ContamW, National Institute of Standards and Technology Documents, no. 5385, Gaithcrsburg, USA 2002.
  • [19] Wargocki P. et al.: Perceived air quality, sick building syndrome symptoms (SBS) and productivity in an office with two different pollution loads, Indoor Air, 9, 165-179 (1999)
  • [20] Wyon D.P.: Healthy Buildings and their Impact on Production, Environmental Technology, 13, 313-322 (1993).
  • [21] Zyska B.: Biological hazards in buildings, Arkady Publishing, Warszawa 1999.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUS2-0009-0084
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.