Benzene air pollution in the Silesian Region

Identyfikatory
Warianty tytułu
PL
Zanieczyszczenie benzenem powietrza w województwie śląskim
Języki publikacji
EN
Abstrakty
EN
The paper presents results of benzene monitoring in ambient air in the Silesian Region (Poland). Sampling points within the Region were chosen with respect to the population density, traffic intensity and presence of industrial emission sources of benzene (coking plants, refineries). Benzene concentrations were measured by means of the passive sampling by using sorption tubes filled with charcoal. The exposure time of each tube was 2 weeks. At each sampling point 12 tubes were exposed from August 2002 to July 2003. The results of the experiment proved differentiated degrees of exposure of the Silesian inhabitants to elevated, exceeding the limit value (5.0 ug/m3), concentrations of benzene. The mean annual concentration of benzene varied over the Region between 4.09 and 9.26 Hg/m3, not exceeding the doubled standard (i.e. the limit plus 100% margin of tolerance, i.e. 10 ug/m3 in total). The limit value for benzene concentration was exceeded at the majority of the sampling points. Results of the exemplary measurement performed in Zabrze with the use of an automatic BTX analyzer are also presented. The parallel exposure of a passive sampler gave similar benzene concentration.
PL
W artykule przedstawiono wyniki monitoringu benzenu w powietrzu, w 19 punktach na terenie województwa śląskiego. Punkty monitoringu wytypowano z uwagi na gęstość zaludnienia i intensywność ruchu samochodowego lub ze względu na obecność przemysłowych źródeł emisji benzenu (koksownie, rafinerie). Pomiary prowadzono metodą pasywną, z zastosowaniem rurek sorpcyjnych wypełnionych węglem aktywnym. Czas ekspozycji rurki - 2 tygodnie. W każdym punkcie, w okresie od sierpnia 2002 r. do lipca 2003 r. wykonano 12 ekspozycji. Wyniki pomiarów wykazały zróżnicowane narażenie mieszkańców śląskich miast na ponadnormatywne stężenie benzenu. Stężenie średnioroczne przyjmowało wartości z zakresu 4,09 ug/m3 do 9,26 ug/m3, a więc nie przekroczyło wartości dopuszczalnej wraz ze 100% marginesem tolerancji. W większości punktów zostało przekroczone średnioroczne stężenie dopuszczalne 5 ug/m3. Przedstawiono również wyniki przykładowej sesji pomiarowej w Zabrzu przy użyciu automatycznego analizatora BTX. W równolegle prowadzonej ekspozycji próbnika pasywnego uzyskano podobną wartość stężenia benzenu, jak w pomiarach automatycznych.
Rocznik
Strony
25--36
Opis fizyczny
Bibliogr. 14 poz., tab., wykr.
Twórcy
autor
  • Institute of Environmental Engineering of the Polish Academy of Sciences, ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze, Poland
  • Institute of Environmental Engineering of the Polish Academy of Sciences, ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze, Poland
  • Institute of Environmental Engineering of the Polish Academy of Sciences, ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze, Poland
autor
  • Institute of Environmental Engineering of the Polish Academy of Sciences, ul. M. Skłodowskiej-Curie 34, 41-819 Zabrze, Poland
Bibliografia
  • [1]. Bartulewicz J., J. Gawłowski, H. Bartulewicz: Pobieranie i przygotowanie próbek do analizy zanieczyszczeń organicznych metodami chromatografii, PIOŚ, Biblioteka Monitoringu Środowiska, Warszawa 1997.
  • [2] Brown R.H.: Monitoring the ambient environment with diffusive samplers. Theory and practical considerations, Journal of Environment Monitoring, 2, 1-9 (2000).
  • [3] Brown R.H., Th.L. Hafkenscheid, K.J. Saunders, A. Borowiak, E. Dc Sacger (eds): Proceedings of International Conference Measuring Air Pollutants by Diffusive Sampling, Montpellier, France, September 26-28, 2001.
  • [4] Council Directive 96/62/EC of September 27, 1996, on ambient air quality assessment and management. Official Journal of the European Communities, October 10, 1996.
  • [5] Czaplicka M., K. Klejnowski: Determination of volatile organic compounds in ambient air. Comparison of methods. Journal of Chromatography A, 976, 369-376 (2002).
  • [6] Directive 2000/69/EC of the European Parliament and of the Council of November 16, 2000, relating to limit values for benzene and carbon monoxide in ambient air, Official Journal of the European Communities, December 13, 2000.
  • [7] GIOS: Wskazówki do modernizacji monitoringu jakości powietrza pod kątem dostosowania systemu do wymagań przepisów Unii Europejskiej ze szczególnym uwzględnieniem dużych miast, Biblioteka Monitoringu Środowiska, Warszawa 2000.
  • [8] Flangartner M.: Practical approach of uncertainty measurement in ambient monitoring by diffusive samplers, [in:] Proceedings of International Conference QA/QC in the Field of Emission and Air Quality Measurements, Prague, Czech Republic May 21-23, 2003, 183-190.
  • [9] IPIŚ PAN: Monitoring benzenu w województwie śląskim w 2002 r, Etap III, C2-122/2002/NI-K, Zabrze 2003.
  • [10] IPIŚ PAN: Monitoring benzenu oraz pyłu PM2.5 w województwie śląskim w 2003 r., Etap I i II, C2- 223/2003/NI-K, Zabrze 2003.
  • [11] Kalina A., D. Krochmal: Oznaczanie gazowych zanieczyszczeń powietrza za pomocą dozymetrów pasywnych, CIOP, Warszawa 1999.
  • [12] Namieśnik J., Z. Jamrógiewicz (red.): Fizykochemiczne metody kontroli zanieczyszczeń środowiska, WNT, Warszawa 1998.
  • [13] Pfeffer H.U., L. Breuer: BTX measurements with diffusive samplers. Comparison between ORSA- type samplers and pumped sampling. Journal of Environment Monitoring, 2, 483-486 (2000).
  • [14] Rozporządzenie Ministra Środowiska z 6 czerwca 2002 r. w sprawie oceny poziomów substancji w powietrzu (Dz. U. Nr 87, poz. 798).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUS2-0008-0093
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.