PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Laboratory automatic measuring system for gamma specimens

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
Proceedings of the International Conference on Development and Applications of Nuclear Technologies NUTECH-2011, 11-14 September 2011, Kraków, Poland
Języki publikacji
EN
Abstrakty
EN
LG Gamma Counter is designed for low activity measurement of the radioactive isotope iodine 125I in liquid or solid samples during radioimmunoassay (RIA) and immunoradiometric assay (IRMA) in small or medium size clinic laboratories. Apart from RIA and IRMA programmed procedures, a measurement of small activity gamma samples is possible. The well scintillator NaI(Tl) is used as radiation detector for the isotope 125 I in the measuring channel, the well dimensions fi being 17 x 38 mm. Gamma Counter was adapted for measuring radioactivity of single samples. The counter is equipped with an automatic system allowing transportation of examined samples to a scintillator well. The gauge is based on an integrated computer which is working under the control of Windows CE and is equipped with special software allowing for setting measurement parameters and communication with an external computer. The measured sample is placed inside the scintillator well either by an automatic sample feeder or manually. The pulses from a photomultiplier tube after amplification and shaping in pulse amplifiers are counted in the window of a single channel analyser by a programmable pulse counter under the control of microprocessor system. The measured count rate is the measure of activity of the assayed sample. Expected count rate error due to unstable operation of amplification is lower than 1%.
Czasopismo
Rocznik
Strony
633--635
Opis fizyczny
Bibliogr. 2 poz., rys.
Twórcy
autor
autor
autor
autor
autor
  • Institute of Nuclear Chemistry and Technology, 16 Dorodna Str., 03-195 Warsaw, Poland, Tel.: +48 22 504 1218, Fax: +48 22 811 1532, a.jakowiuk@ichtj.waw.pl
Bibliografia
  • 1. Chard T (1995) An introduction to radioimmunoassay and related techniques, 5th ed. Elsevier, Amsterdam, New Jork
  • 2. Packard cobra gamma counters. http://www.gmi-inc.com/Packard-Cobra-Gamma-Counter.html
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUJ8-0023-0061
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.