Tytuł artykułu

Frequency characteristic of an optopneumatic detector

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In this paper, a single-beam optopneumatic detector with two chambers was considered. On the base of a mathematical model its frequency characteristic was determined and an influence of various factors on amplitude of gas flow between the detector chambers was investigated. It was found that this flow appears as a result of a phase difference in pressure oscillations at both chambers. According to the assumed model the signal from the detector should rich a maximum value within the range of about 1 – 100 Hz but an examined detector shows the signal decreasing from 1 Hz. It is caused by large time constant of a sensor measuring the flow between the detector chambers.
Słowa kluczowe
Rocznik
Tom
Strony
131--136
Opis fizyczny
Bibliogr. 14 poz., rys.
Twórcy
autor
autor
autor
  • Institute of Chemistry, Military University of Technology, 00-908 Warsaw, Poland
Bibliografia
  • 1. Yoh-Han Pao (ed.), Optoacoustic Spectroscopy and Detection (Academic Press, New York, 1977).
  • 2. A. Rosencwaig, Photoacoustics and Photoacoustic Spectroscopy (Willey, New York, 1980).
  • 3. J. A. Jahnke, Continous Emission Monitoring, (Van Nostrand Reinhold, New York, 1993).
  • 4. M.Siegert, Air monitoring by spectroscopic technique (Wiley, New York, 1994)
  • 5. K. Yamashita, A. Murata, M. Okuyama, Sens. Actuators A 66, 29-32 (1998)
  • 6. A.M. Ferber, P.Ohlckers, H. Rogne, M.H. Lloyd, in Proceedings of The MTEC International Conference on Sensors & Transducters, Birmingham, UK, 2001
  • 7. K. Jasek, Application of optopneumatic detectors for determination of sulfur content in solid fuels (in Polish), Ph.D. thesis, Military University of Technology, Warsaw 1998.
  • 8. K. Jasek, A. Knap, J. Puton, in Proceedings of V Konferencja Naukowa Czujniki Optoelektroniczne i Elektroniczne, Jurata 1998, 111-114.
  • 9. Cataloge Simens PA 10 News, ULTRAMAT 6 Gas Analyzers for the Determination of IR-active Components, January 2005.
  • 10. S. Wu, Q. Lin, Y. Yuen, Y.-Ch. Tai, Sens. Actuators A 89, 152-158 (2001).
  • 11. A. Rasmussen, C. Mavriplis, M.E. Zaghloul, O. Mikulchenko, K. Mayaram, Sens.Actuators A 88, 121-132 (2001).
  • 12. J. Filipiak, L. Solorz, K. Zubko, Molecular and Quantum Acoustics 25, 89-100 (2004).
  • 13. T. Pustelny, J. Ignac-Nowicka, Z. Opilski, Molecular and Quantum Acoustics 25, 201-210 (2004).
  • 14. F. Kohl, R. Fasching, F. Keplinger, R.Chabicovsky, A. Jachimowicz, G. Urban, Measurement 33 109-119 (2003).