The design of an insulin pump concept of closing the loop

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
8th International Conference on Global Research and Education – Inter-Academia 2009
Języki publikacji
EN
Abstrakty
EN
This paper explains what insulin pump is and outlines basic requirements for such device. The material presented in this paper is an attempt to collect actual knowledge about closed loop insulin delivery systems. From scientific point of view we are going to propose the closed loop insulin-dispensing device with control built on the base of predictive neural network system. The blocks of such systems are listed, and main problems to overcome are defined.
Słowa kluczowe
Twórcy
autor
  • Institute of Metrology and Biomedical Engineering, Warsaw University of Technology, Faculty of Mechatronics, Św. Andrzeja Boboli 8, Warszawa, 02-525, Poland, h.hawlas@mchtr.pw.edu.pl
Bibliografia
  • [1] Tatoń J., “Cukrzyca wymagająca wstrzyknięć insuliny Poradnik dla pacjentów”, 1 ed. Warszawa: Wydawnictwo Lekarskie PZWL, 1998, p. 424 and f. (in Polish)
  • [2] Your Insulin Pump Proposals, www.diabeteshealth.com/read/2007/12/13/5586.html
  • [3] Symlin Word Wide Web,www.symlin.com
  • [4] Friedrich M.J., “Artificial Pancreas May Soon Be a Reality”,JAMA, vol. 301, issue 15, Apr. 2009, pp. 1525-527.
  • [5] Hovorka R., Chassin L.J., Wilinska M.E., Canonico V., Akwi J.A., Federici M.O., Massi-Benedetti M., Hutzli I., Zaugg C., Kaufmann H., Both M., Vering T., Schaller H.C., Schaupp L., Bodenlenz M., Pieber T.R., „Closing the loop: the adicol experience”,Diabetes Technol. Ther., vol. 6, issue 3, 2004, pp. 307-318.
  • [6] Wentholt I.M., Vollebregt M.A., Hart A.A., Hoekstra J.B., DeVries J.H., “Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients”, Diabetes Care, vol. 28, issue 12, December 2005, pp. 2871-2876.
  • [7] Steil G.M., Rebrin K., Mastrototaro J., Bernaba B., Saad M.F., “Diabetes Technology & Therapeutics”, vol. 5, issue 1, January 2003, pp. 27-31.
  • [8] Kovatchev B., Anderson S., Heinemann L., Clarke W.,“Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors”, Diabetes Care, vol. 31, issue 6, June 2008, pp. 1160-1164.
  • [9] Weinzimer S.A., Steil G.M., Swan K.L., Dziura J., Kurtz N., Tamborlane W.V., “Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial Pancreas”, May 2008, vol. 31, pp. 934-939.
  • [10] El Youssef J., Castle J., Ward W., “A Review of Closed-Loop Algorithms for Glycemic Control in the Treatment of Type 1 Diabetes”, Algorithms, vol. 2, issue 1, 2009, pp. 518-532.
  • [11] Lewenstein K., Czerwińska D., „Prediction of Twenty four hour insuline doses and glycaemia profiles in a neural network based system”,Pol. J. of Med. Phys.and Eng., vol. 5, issue 1, 1999, pp. 21-33.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUJ7-0006-0057
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.