MR Imaging of Mouse Heart in vivo Using a Specialized Probehead and Gradient System

Identyfikatory
Warianty tytułu
Konferencja
1st Symp. on NMR in Chemistry, Biology and Medicine; 8-10 Semptember, Warsaw, Poland. Issue dedicated to honour Prof. Witanowski
Języki publikacji
EN
Abstrakty
EN
Preliminary results of Magnetic Resonance Imaging (MRI) of cardiac function in mice in vivo, using the homebuilt gradient coils and specialized RF probehead are demonstrated. An unshielded gradient system with inner diameter of 60 mm was designed and constructed for the 4.7T/310 magnet with MARAN DRX console (Resonance Instruments). Dedicated probehead, constructed to fit the gradient system, consists of the RF birdcage coil and the animal handling system. ECG-triggered cine images of eight FVB (wild-type) and four transgenic micewith heart failure (Tg alfa q*44) were acquired at physiological temperature (37 graduate C) with a good quality of multislice images in different phases of the cardiac cycle, as well as a good contrast between myocardium and flowing blood. This technique allowed the calculation of the end-diastolic (EDV) and end-systolic (ESV) volumes of working heart that could be used to monitor the development of heart failure in vivo in Tg alfa q*44 mice.
Słowa kluczowe
EN
Rocznik
Strony
1133--1139
Opis fizyczny
Bibliogr. 9 poz., rys.
Twórcy
autor
autor
  • H. Niewodniczański Institute of Nuclear Physics PAS, Radzikowskiego 152, 31-342 Kraków, Poland
Bibliografia
  • 1. Mende U., Kagen A., Cohen A., Aramburu J., Schoen F.J. and Neer E., Proc. Nat. Acad. USA, 95,13893 (1998).
  • 2. Mende U., Semsarian C., Martins D.C., Kagen A., Duffy C., Schöen FJ. and Neer E.J., J. Mol. Cell. Cardiol.,33, 1477(2001).
  • 3. Earls J.P., Ho Y.B., Foo T.K., Castillo E. and Flamm S.D., J. Magn. Reson. Imaging, 16, 111 (2002).
  • 4. Franco F., Dubois S., Peshock R.M. and Shohet R.V., Am. J. Physiol., 274, H679 (1998).
  • 5. Turner R., J. Phys. E: Sci. Instrum., 21, 948 (1998).
  • 6. Chin Ch., Collins Ch.M., Li S., Dardzinski B.J. and Smith M., Concepts Magn. Reson. (Magnetic Resonance Engineering), 15(2), 156 (2002).
  • 7. WiessmanF., Ruff J., Englenhardt S., Hein L., DieneshCh. andLeupold A., Circ. Res., 88,563 (2001).
  • 8. Qiu H.H., Cofer G.P., Hedlund L.W. and Johnson G.A., IEEE Trans. Biomed. Eng., 44, No. 11, November 1997.
  • 9. Haacke E.M., Brown R.W., Thompson M.R. and Venkatesan R., Magnetic Resonance Imaging. Physical Principles and Sequence Design. John Wiley & Sons, New York, 1999.