In this paper a laboratory set-up with an electron linac installed in this Institute, and an attached narrow-beam collimator for photon beam are presented. Characteristics of the circular photon beams of diameters ranging from 10 to 30 mm at the isocentre are reported. The specific quantities measured include: relative output factors, beam profiles (off axis factors), and a central axis attenuation of beams. Measurements of these parameters were performed in a water phantom using small cylindrical ionisation chambers.
Słowa kluczowe
Czasopismo
Rocznik
Strony
91--93
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
  • The Andrzej Sołtan Institute for Nuclear Studies, Department of Accelerator Physics, 05-400 Świerk, Poland Tel.: +4822/ 7180416, Fax: +4822/ 7793481
  • The Andrzej Sołtan Institute for Nuclear Studies, Department of Accelerator Physics, 05-400 Świerk, Poland Tel.: +4822/ 7180416, Fax: +4822/ 7793481
Bibliografia
  • 1. Graham JG, Warrington AP, Gill SS, Brada M (1991) A noninvasive relocatable stereotactic frame for f rationated radiotherapy and multiple imaging. Radiother Oncol 21:60–62
  • 2. Hartmann G, Wysocka A (1995) Test reports of the PLATO stereotactic radiosurgery software ACTIVITY - Int NucletronOldelf. Rad J Special Report 6:56–62
  • 3. Podgorsak EB, Pike B, Olivier A, Pla M, Souhami L (1989) Radiosurgery with high energy photon beams: a comparison among techniques. Int J Rad Oncol Biol Phys 16:857–865
  • 4. Serago CF, Houdek PV, Hartmann GH, Saini DS, Serago ME, Kaydee A (1992) Tissue maximum ratios (and other parameters) of small circular 4, 6, 10, 15 and 24 MV X-ray beams for radiosurgery. Phys Med Biol 37;10:1943–1956
  • 5. Wysocka A (1996) Physical aspect of stereotactic radiosurgery with application of the linear accelerator arc method. Nukleonika 41;2:11–20
  • 6. Wysocka A (1998) Physical aspects of treatment planning in linacbased radiosurgery of intracranial lesions. Reports of Practical Oncology and Radiotherapy 3;3:59–66
  • 7. Wysocka A, Rostkowska J, Kania M, Bulski W, Fijuth J (2000) Dosimetric characteristics of circular 6 MV X-ray beams for stereotactic radiotherapy with a linear accelerator. Acta Phys Pol B 31;1:81–87