Abstract In this work, the mass throughput rate in a radiation processing center, equipped with an X-ray facility, is calculated by means of a curve against the thickness of the material, along with the variation of dose uniformity. Therefore, depending on the desired dose value, the best thickness and the mass throughput rate can be calculated. The calculation results for the 5 and 10 MeV X-ray bremsstrahlung for polyethylene and wood as the irradiation products, have been obtained by using a Monte-Carlo computer code. In addition, the experimental results at the same geometry and materials were compared with those calculated.
Czasopismo
Rocznik
Strony
121--124
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
  • Yazd Radiation Processing Center (YRPC), P. O. Box 89175-389, Yazd, Iran, Tel.: +98 352 623 4840, Fax: +98 352 623 4740
autor
  • Yazd Radiation Processing Center (YRPC), P. O. Box 89175-389, Yazd, Iran, Tel.: +98 352 623 4840, Fax: +98 352 623 4740
Bibliografia
  • 1. Farrell JP, Seltzer SM, Silverman J (1988) Bremsstrah-lung generators for radiation processing. Radiat Phys Chem 22;3/5:469−478.
  • 2. Hoshi Y, Sakamoto I, Takehisa M, Sato T, Tanaka S, Agematasu T (1994) X-ray irradiation system for steriliza-tion application. Nucl Instrum Meth A 353:6−9.
  • 3. Nelson WR, Hirayama H, Rogers DWO (1985) The EGS4 Code System. Stanford Linear Accelerator Center, Stanford University, Stanford, California, 94305.
  • 4. Seltzer SM, Farrell JP, Silverman J (1983) Bremsstrah-lung beam for high-power electron accelerators. IEEE T Nucl Sci 30;2:1629−1633.
  • 5. Takehisa M, Saito T, Takahashi T, Sato Y, Sato T (1993) Characteristics of a contract electron beam and brem-sstrahlung (X-ray) irradiation facility of radia industry. Radiat Phys Chem 42;1/3:495−498.
  • 6. Ziaie F, Afarideh H, Hadji-Saeid SM, Durrani SA (2001) Investigation of beam uniformity in industrial electron accelerator. Radiat Meas 34:609−613.
  • 7. Ziaie F, Zimek Z, Bulka S, Afarideh H, Hadji-Saeid SM (2002) Calculated and measured dose distribution in electron and X-ray irradiated water phantom. Radiat Phys Chem 63;2:177−183.