PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Development of diagnostic tools for Plasma Focus derived X-ray source

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
Proceedings of the 2nd IAEA Research Co-ordination Meeting of the Co-ordinated Research Project on Dense Magnetized Plasma 1-3 June 2005, Kudowa Zdrój, Poland
Języki publikacji
EN
Abstrakty
EN
The energy spectra of X-rays generated by the impact of electron beams on high- and medium-Z targets following the pinch implosion of Plasma Focus (PF) devices are discussed in terms of the possible mechanisms of X-ray production following electron impact ionization. In addition, the temperature measurement of the PF inner electrode is reported and some results have been proved useful in order to optimize the device functionalities.
Czasopismo
Rocznik
Strony
15--20
Opis fizyczny
Bibliogr. 11 poz., rys.
Twórcy
autor
autor
autor
autor
autor
autor
autor
autor
autor
autor
  • Department of Physics, University of Ferrara, 1 Saragat Str., I-44100 Ferrara, Italy and INFM, Genova, Italy, Tel.: +39 0532 974211, Fax: +39 0532 974210,, tartari@fe.infn.it
Bibliografia
  • 1. Birch R, Marshall B, Ardran GM (1979) Catalogue of spectral data for diagnostic X-rays. HPA, London, SRS 30
  • 2. Bostik WH, Nardi V, Prior W et al. (1983) Production of GW electron and ion beams by focused discharges. In:Nardi V, Salin H, Bostik WH (eds) Energy storage,compression and switching. Plenum Press, New York,pp 267−287
  • 3. Casnati E, Tartari A, Baraldi C (1982) An empirical approach to K-shell ionization cross section by electrons.J Phys B-At Mol Opt 15:155−167
  • 4. Gribkov VA (2000) On possible formulation of problems of a dense Plasma Focus used in material science.Nukleonika 43;3:149−153
  • 5. Horowitz YS, Kalef-Ezra J (1981) Relative thermoluminescent response of LiF TLD. Nucl Instrum Meth 188:603−607
  • 6. Hubbell JH, Seltzer SM (1995) Tables of X-ray mass attenuation coefficients and mass energy absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetric interest.NSTIR 5632, Gaithersburg MD, USA
  • 7. Jacobs VL, Davis J, Balazs SF, Cooper JW (1980) Multiple ionization and X-ray emission accompanying the cascade decay of inner shell vacancies in Fe. Phys Rev A 21:1917−1926
  • 8. Marziani M, Gambaccini M, Tavora L, Taibi A (2001) Monte Carlo simulation of mammography X-ray units: a comparison between different electron extensions of the EGS4 code system. In: Khing A, Barão F, Nakagawa N, Tavora L, Vaz P (eds) Advances Monte Carlo for radiation physics, particle transport simulation and applications. Springer-Verlag, Berlin, pp 351−356
  • 9. Schnuerer M, Nolte R, Sclegel T et al. (1997) On the distribution of hot electrons produced in short pulse laser plasma interaction. J Phys B-At Mol Opt 30:4653−4661
  • 10. Tartari A, Da Re A, Bonifazzi C, Marziani M (2004) Energy spectra measurements of X-ray emission from electron interaction in a dense Plasma Focus device. Nucl Instrum Meth B 213:206−209
  • 11.Tartari A, Verri G, Da Re A, Mezzetti F, Bonifazzi C, Rapezzi L (2002) Improvement of calibration assessment for gold fast neutron activation analysis using Plasma Focus devices. Meas Sci Technol 13:939−945
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUJ6-0004-0002
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.