The purpose of this investigation is the determination of a simple criterion of local space charge effect in conventional avalanche counters at moderate specific ionization. Parallel-plate avalanche counters (PPAC) with an electrode spacing d from 0.1 to 0.4 cm have been used to register low-energy alpha particles at n-heptane vapour pressures of p ? 5 Torr. The criterion determined is a simple h/pm function describing the variability of the product of effective gas amplification and actual particle energy loss, where both the numerical h coefficient and the exponent m assume different values for the various values of d. The product variability at higher gas pressures in PPAC detector – having regard to practical side of criterion determined – can be relatively well described by a single linear function. The results obtained are discussed from their veracity point of view.
Czasopismo
Rocznik
Tom
Strony
125--131
Opis fizyczny
Bibliogr. 21 poz., rys.
Twórcy
autor
- Department of Nuclear Spectroscopy and Technique, The Andrzej Sołtan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland Tel.: +4822/ 7180461, Fax: +4822/ 7793481, sernicki@india.ipj.gov.pl
Bibliografia
- 1. Breskin A, Zwang N (1977) Timing properties of parallel plate avalanche counters with light particles. Nucl Instr Meth 144:609–611
- 2. Brunner G (1978) Townsend coefficient of gases in avalanche counters. Nucl Instr Meth 154:159–163
- 3. Culhane Jl, Sanford PW (1966) High gain saturation effects in proportional counters. Rev Sci Instrum 37:1424–1425
- 4. Hanna GC, Kirkwood DHW, Pontecorvo B (1949) High multiplication proportional counters for energy measurements. Phys Rev 75:985– 986
- 5. Kazerouni MA, Käppeler F (1979) A fast spherical avalanche fission detector with intrinsic α-discrimination. Nucl Instr Meth 164:439–445
- 6. Kotov AA, Neubert W, Andronenko LN, Gorshkov BL, Kovshevny GG, Vaishnene LA, Yazikov MI (1980) Application of parallel plate avalanche counters for proton induced fission studies. Nucl Instr Meth 178:55–60
- 7. Krusche A, Bloess D, Münnich F (1967) Über die Eigenschaften eines Parallelpltten-lawinenzählers zur Messung von Lebensdauern Angeregter kernniveaus. Nucl Instr Meth 51:197–209
- 8. Lakshminarasimha CS, Lucas J, Kontoleon N (1974) Diffusion and ionization studies for electron swarms in carbon monoxide and carbon dioxide. J Phys D 7:2545–2553
- 9. Maidikov VZ, Surovitskaya NT, Skobelev NK, Neubert W (1982) A spectrometer for measuring heavy reaction products. Nucl Instr Meth 192:295–300
- 10. Northcliffe LC, Schilling RF (1970) Nucl Data Tables A 7:233
- 11. Prete G, Viesti G (1985) Discrimination capability of avalanche counters detecting different ionizing particles. Nucl Instr Meth A 234:276–280
- 12. Raether H (1964) Electron avalanches and breakdown in gases. Butterworths, London
- 13. Richter KZ (1959) Die Trägervermehrung einer Lawine mit Eigenraumladung. Physik 157:130–133
- 14. Sernicki J (1983) A versatile large area parallel plate avalanche counter (PPAC) for broad-range magnetic spectrographs. Nucl Instr Meth 212:195–201
- 15. Sernicki J (1985) Some studies on the electrical strength of large area transmission avalanche counters. Nucl Instr Meth A 234:527–534
- 16. Sernicki J (1986) Timing properties of transmission avalanche counters at moderate specific ionization. Nucl Instr Meth A 251:81–88
- 17. Sernicki J (1988) Behaviour and response veracity of large area transmission avalanche counters as elementary detecting devices. Nucl Instr Meth A 263:446–456
- 18. Sernicki J (1990) First Townsend coefficient of organic vapour in avalanche counters. Nucl Instr Meth A 288:555–570
- 19. Sernicki J (1997) Some practical data on the first Townsend coefficient of organic vapour in avalanche counters. Nucl Instr Meth A 399:347–353
- 20. Stelzer H (1976) A large area parallel plate avalanche counter. Nucl Instr Meth 133:409–413
- 21. Walzog D, Neubert W, Sodan H, Skobelev NK (1978) On a possibility of identification of nuclear reaction products by means of avalanche counters. Preprint JINR P7–11578. Dubna