AIC-144 cyclotron: present status

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
Proceedings of the XXXIII European Cyclotron Progress Meeting, 17-21 September 2002, Warszawa-Kraków, Poland
Języki publikacji
EN
Abstrakty
EN
The presented AIC-144 cyclotron was designed and constructed 20 years ago in the Institute of Nuclear Physics in Kraków (Poland). Later on it was modernized, after the decision of creating the Hadron Radiotherapy Centre in Kraków was taken by the government. At present, the cyclotron is capable to deliver beams of protons (with energy up to 60 MeV), deuterons (with energy up to 30 MeV) and a-particles (with energy up to 60 MeV). The magnetic structure and the RF system were modernized (a new HF generator with output power 120 kW and frequency range 10-27 MHz was installed; an RF cavity resonator was reconstructed to improve the Q-factor at the highest frequencies). The new PIG source and system of central diaphragms was built to improve beams quality on the first turns. The single lamella and multilamella probes were fully reconstructed. Special effort was put on a highly efficient extraction system. The precession method for particles extraction was chosen as the best one. All computer simulations and experimental runs were done in close cooperation with specialists from the Laboratory of Nuclear Problems JINR, Dubna. The extraction system consists of 2 electrostatic deflectors, 3 magnetic channels (passive) and 4 coils for shaping of the 1st harmonic. So far, the beam extraction experiments were carried out for the proton beams with the final energy of 35 MeV, 48 MeV and 60 MeV. For all these energies the efficiency of extraction was above 50%. A computer remote control of the main magnet power supply and of the 24 correction coils was installed and put into operation. In the last 3 years, the internal beams of protons and a-particles were used to produce radioisotopes like 11C, 57Co, 83-85Sr, 102Rh, 111In, 173-175Hf, 178-181W.
Czasopismo
Rocznik
Strony
117--121
Opis fizyczny
Bibliogr. 7 poz., rys.
Twórcy
autor
  • The Henryk Niewodniczański Institute of Nuclear Physics, 152 Radzikowskiego Str., 31-342 Kraków, Poland, Tel.: +48 12/ 662 84 96, Fax: +48 12/ 662 84 58
  • The Henryk Niewodniczański Institute of Nuclear Physics, 152 Radzikowskiego Str., 31-342 Kraków, Poland, Tel.: +48 12/ 662 84 96, Fax: +48 12/ 662 84 58
  • The Henryk Niewodniczański Institute of Nuclear Physics, 152 Radzikowskiego Str., 31-342 Kraków, Poland, Tel.: +48 12/ 662 84 96, Fax: +48 12/ 662 84 58
Bibliografia
  • 1. Bakewicz E, Daniel K, Doruch H et al. (2001) A new extraction system for the upgraded AIC-144 cyclotron. Nukleonika 46;2:51−57
  • 2. Borisov ON, Morozov NA, Samsonov EV et al. (1996) Feasibility study of the beam extraction from the AIC-144 cyclotron. Report JINR E9-96-492. JINR, Dubna
  • 3. Dora J (1996) Resonant power supply. Polish Patent no. 313150
  • 4. Kian IN, Vorojtsov SB, Taraszkiewicz R (2002) Betatron Oscillation Frequencies Calculation Program (Betatron Oscillation Research Program – BORP). Report JINR P9-2002-171. JINR, Dubna
  • 5. Kian IN, Vorojtsov SB, Taraszkiewicz R (2002) Mean Magnetic Field Calculation Program with allowance for flutter for isochronous cyclotron (Cyclotron Analytic Model Program − CAMP). Report JINR P9-2002-170. JINR, Dubna
  • 6. Morozov NA, Bakewicz E, Daniel K et al. (2002) The passive magnetic channel (MC-3) for the beam extraction system of isochronous cyclotron AIC-144. Communication JINR P9-2002-18. JINR, Dubna
  • 7. Schwabe JA (1997) AIC-144 – Automatic isochronous cyclotron: main parameters, status. Nukleonika 42;3:727−770
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BUJ5-0004-0079
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.