The influence of wood based products loading on formaldehyde concentration in indoor environment of buildings

Identyfikatory
Warianty tytułu
Konferencja
IX Konferencja Naukowa Rzeszowsko-Lwowsko-Koszycka Aktualne problemy budownictwa i inżynierii środowiska. Jakość - Niezawodność - Bezpieczeństwo, Rzeszów, 3-4 września 2004. Cz.2. Inżynieria Środowiska
Języki publikacji
EN
Abstrakty
EN
In this contribution are presented the results of monitoring of formaldehyde concentration level from particleboard furniture in indoor environment of paneled and walled houses in Slovakia. The monitoring of formaldehyde emission was performed in living rooms, children's rooms, bedrooms and kitchens all the year round. Although there were formaldehyde concentrations below the highest allowed formaldehyde concentration (60 microgram/m3), there was proved correlation logarithmic dependence between the average long term formaldehyde concentration and degree of loading space by particleboard furniture. Measurements showed that children's rooms and bedrooms represent the hazard for health of inhabitants because of their largest loading by particleboard furniture in this environment.
Twórcy
  • Technical University of Kosice, Faculty of Civil Engineering, Department of Environmental Engineering
autor
  • Technical University of Kosice, Faculty of Civil Engineering, Department of Environmental Engineering
Bibliografia
  • [1]. www.cefic.be/Files/Publications/formaldehyde-updated.doc
  • [2]. www.umn.edu/eoh/5103/air/formaldehyde.html
  • [3]. Meyer, B., Kottes, A.B., Reinhardt, R.M.: Formaldehyde release from wood products. In: ACS Symp Ser 316. Proc 189th Meet Am Chem Soc, Florida, 1985.
  • [4]. Roffael, E.: Formaldehyde release from particleboard and other wood-based panels. In: Malayan Forest Records No 37. Kuala Lumpur, Forest Research Institute Malaysia, 1993.
  • [5]. EN 120 Wood-based panels. Determination of formaldehyde content. Extraction method called the perforator method.
  • [6]. Acta Hygienica and Epidemiologica Materialia. The uniform method of formaldehyde concentration measurement in interiors on the particleboard base. The section no. 9, 1989.