PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Analysis of the error caused by possible displacements of the reference axis used for the assessment of geometrical deviations of cylindrical machine elements

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Analiza błędu spowodowanego możliwością zmiany położenia osi odniesienia przyjętej do oceny odchyłek geometrycznych zespołu powierzchni cylindrycznych
Języki publikacji
EN
Abstrakty
EN
A comprehensive analysis of one component of total error occurring in the determination of geometrical deviations of machine elements set in V-blocks is presented. Analyzed is the error component arising due to possible displacement of the reference axis adopted for the assessment of geometrical deviations, reference axis position in particular. Changes in the position of that axis may result form displacements of measured roundness profile centres that define the reference line. The analysis also allowed to determine the relative error values of the determined deviation of axis position resulting from changes in reference axis position.
PL
W artykule przedstawiona została analiza jednej ze składowych sumarycznego błędu wyznaczania odchyłek geometrycznych części maszyn bazowanych w pryzmach. Przedstawiona analiza jest częścią szeroko pojętej teoretycznej analizy błędów opracowanej metodyki pomiarów odchyłek geometrycznych zespołu powierzchni cylindrycznych elementów maszyn, które z uwagi na swoje duże gabaryty i masy bazowane są najczęściej w pryzmach. Analizowano składową błędu spowodowaną możliwością zmiany położenia osi odniesienia przyjętej do oceny odchyłek geometrycznych, w szczególności odchyłki położenia osi. Zmiany położenia tej osi wynikać mogą z przemieszczeń środków mierzonych zarysów okrągłości, w oparciu o które wyznaczana jest oś odniesienia. W wyniku przeprowadzonej analizy wyznaczone zostały wielkość pola i granice możliwych przemieszczeń punktu usytuowanego na zmieniającej swoje położenie osi odniesienia, w zależności od zmieniającego również swoje położenie punktu usytuowanego na osi rozpatrywanej powierzchni cylindrycznej. Wymienione punkty określają odległość odpowiadającą (zgodnie z przyjętym kryterium tworzenia elementów odniesienia i sposobem wyznaczania odchyłek geometrycznych) poszukiwanej odchyłce współosiowości. W oparciu o przeprowadzoną analizę określone zostały również wartości błędu względnego wyznaczanej odchyłki położenia osi, wynikającego ze zmian położenia osi odniesienia przyjętej do oceny odchyłek geometrycznych.
Wydawca
Rocznik
Strony
1068--1071
Opis fizyczny
Bibliogr. 14 poz., rys., wykr., wzo
Twórcy
Bibliografia
  • [1] Nozdrzykowski K.: Analysis of the displacement of a V-block supported object. Przegląd Mechaniczny, No. 9/2007, pp. 32-35 (in Polish).
  • [2] Adamczak S.: Reference methods of machine parts roundness profile measurements. Monografie, Studia, Rozprawy. Politechnika Świętokrzyska, Kielce, 1998 (in Polish).
  • [3] Pabian A.: Accuracy of V-block support. Mechanik, No. 12/1983, pp. 721-723 (in Polish).
  • [4] Sonozaki S., Fujiwara H.: Simultaneous Measurement of Cylindrical Parts Profile Rotating Accuracy Using Multi-Three-Point-Method. Journal Japan Soc. of Prec. Eng. vol. 23, No. 4, 1983, pp. 286-291.
  • [5] Nyberg T. R., Kotamaki M.: Cylindricity Measurement of Large Rollers by Combined 3-point-metod and Sequential 2-point-metod. Proceedings of 4th International Symposium on Dimensional Metrology in Production and Quality Control, ISMQC, Tampere 1992.
  • [6] Nozdrzykowski K.: A criterion for selecting characteristic dimensions of a roller vee block. Maintenance Problems, Nr 3/2007, pp. 167-173.
  • [7] Nozdrzykowski K., Kuźniewski B.: Estimation of errors for the geometric deviations. Proceedings of XVI IMEKO World Congress Viena, 2000, Volume IX, pp. 141-144.
  • [8] Nozdrzykowski K.: Harmonic analysis and methods of determining profile and axis position deviations of cylindrical surfaces using DEVFORMLOC-NKŁN software. Pomiary Automatyka Kontrola, No. 1/2010,pp. 68-69 (in Polish).
  • [9] Nozdrzykowski K.: Determination and Analysis of the Combined Measurement Uncertainty od Coaxiality Deviation. Polish Jornal of Environmental Studies, Vol. 18, No. 2A, 2009, pp. 170-175.
  • [10] Adamczak S., Domagalski R., Janecki D.: Experimental into the significance of determination of harmonic roundness profiles and surface waviness, 9th DAAAM International Symposium, Technical University Cluj-Napoco, Romania 1998.
  • [11] Zieliński T. P.: Wavelet transform applications in instrumentation and measurement: tutorial & literature survey. Metrology and Measurement Systems, Vol. XI-No. 1/2004, pp. 61-71.
  • [12] Diakov D., Kalimanova I., Minakov T.: System for measurements of roundness of large scaled objects. Proceedings of Ist International Scientific-Technical Conference, Metrology in Production Engineering, Kraków, 2003, pp. 121-129.
  • [13] Makieła W., Stępień K.: Assessment of the effect of selected basic wavelet on the wavelet analysis of surface irregularity profiles. Pomiary Automatyka Kontrola, No. 1/2010, pp. 32-34 (in Polish).
  • [14] Adamczak S., Makieła W., Stępień K.: Investigating advantages and disadvantages of the analysis of a geometrical surface structure with the use of Fourier and wavelet transform. Metrology and Measurement Systems,vol. XVII – No. 2/2010.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSW4-0125-0010
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.