Measurements of selected biomechanical parameters during experimental studies of an implant-bone connection
Języki publikacji
PL
Abstrakty
PL
Praca przedstawia jedną z metod badania osadzenia implantu w tkance kostnej. Opisano metodykę badań, dzięki której możliwa jest ocena jakości osadzenia implantu w tkance kostnej. W badaniach eksperymentalnych nowo poznawanych zjawisk kluczowe staje się odpowiednie dobranie aparatury pomiarowej. Poprawny dobór przyrządów pomiarowych pozwala na jednoznaczny opis badanego zjawiska lub obiektu.
EN
The paper presents one of the methods of testing an implant mounting within the osseous tissue. It describes a methodology of the studies, which makes it possible to evaluate quality of the implant mounting within the osseous tissue. In the case of experimental studies of new phenomena being just investigated, it is crucial to appropriately select the measurement equipment. A correct selection of the measuring instruments allows one to unequivocally describe the studied phenomenon or object. A specific character of biomechanical properties of bones makes it impossible to carry out experiments using universal measuring machines, what results in a necessity of building custom test stations as well as special measure-ment systems based on well-developed measurement applications. As far as the described method of testing is concerned, there can be distinguished the following three stages:- the first, including preparations of the objects for the studies,- the second, including carrying out of measurements using the objects that have been prepared beforehand,- the third, including analytical determination of numerical values of the studied parameters. At the first stage, a minimum of the sample should be prepared, using an osseous tissue taken from a closer shaft of a cow thigh bone. After a pretreatment of the bone, a fragment of the tested mandrel should be mounted within it. The test station for experimental studies of the mandrel mounting within the osseous tissue must ensure a possibility of a real-time recording of the related displacements and load forces. The experiment was repeated many times in order to minimize the scatter of the indications. Basing on the obtained results, mutual correlations of particular data were determined, e.g. displacements of the mandrel within the bone in relation to the applied load. The obtained results make it possible to specify what kind of dynamics of the load applying influences the osseous tissue reaction rate.
Wydawca
Rocznik
Strony
575--578
Opis fizyczny
Bibliogr. 3 poz., rys., tab., wykr.
Twórcy
autor
Bibliografia
  • [1] Będziński R.: Biomechanika Inżynierska, zagadnienia wybrane, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław 1997.
  • [2] Zaczyk M., Jasińska-Choromańska D.: Zjawisko kontaktu endoproteza-kość. Materiały II seminarium inżynierii wytwarzania, Kalisz 2008.
  • [3] Zaczyk M., Jasińska-Choromańska D., Miśkiewicz A.: Stanowiska do badań jakości osadzenia trzpienia implantu w kości. Materiały konferencyjne Majówki Młodych Biomechaników, Ustroń 2010.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSW4-0102-0001
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.