Accumulated jitter measurement of standard clock oscillators

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Long term instability of frequency and phase fluctuations of the clock signal are significant source of the measurement error in the precise time-interval measurement systems. In this paper the problem of clock signal instability, fluctuations caused by accumulated clock jitter and their influence on the precision of the time-interval measurement system implemented in the programmable CMOS FPGA devices are discussed. The presented method enables jitter characterization of the reference-clock. Moreover, the time-interval-error in the range up to several miliseconds can be easily and quickly calculated using only two parameters obtained during the calibration process. The described method can be applied in measurement instruments with a precise time-base.
Rocznik
Strony
259--266
Opis fizyczny
Bibliogr. 9 poz., rys., wykr.
Twórcy
autor
autor
autor
  • Nicolaus Copernicus University, Institute of Physics, Department of Technical and Applied Physics, Grudziądzka 5, 87-100 Toruń, Poland, slawg@fizyka.umk.pl
Bibliografia
  • [1] A. Hajimiri, S. Limotyrakis, T.H. Lee: “Jitter and phase noise in ring oscillators”. IEEE Journal of Solid-State Circuits, vol. 34, no. 6, 1999, pp. 790-804.
  • [2] J. Kalisz: “Determination of short-term error caused by the reference clock in precision time-interval measurement and generation”. IEEE Transactions on Instruments and Measurement, vol. 37, no. 2, 1988, pp. 315-316.
  • [3] J. Kalisz: “Review of methods for time interval measurements with picosecond resolution”. Metrologia, no. 41, 2004, pp. 17-32.
  • [4] S. Bregni: “Clock stability characterization and measurement in telecommunications”. IEEE Transactions on Instruments and Measurement, vol. 46, no. 6, 1997, pp. 1284-1294.
  • [5] R. Szymanowski, J. Kalisz: “Field programmable gate array time counter with two-stage interpolation”. Review of Scientific Instruments, vol. 76, no. 4, 2005.
  • [6] M. Zieliński, M. Kowalski, S. Grzelak, D. Chaberski, R. Frankowski: “Influence of clock signal phase fluctuation on the precision of time-interval measurement”. Elektronika, vol. 1, 2006, pp. 50-55.
  • [7] E. Rubiola: “On the measurement of frequency and of its sample variance with high-resolution counters”. Review of Scientific Instruments, vol. 76, 2005.
  • [8] M. Zieliński, R.S. Dygdała, K. Karasek, A. Zawadzka: “Real-time multichannel scaler measurement of oscillator instabilities”. Review of Scientific Instruments, vol. 71, no. 6, 2000, pp. 2577-2581.
  • [9] M. Zieliński, M. Kowalski, D. Chaberski, S. Grzelak, R. Frankowski: “Measurement system of oscillators’ phase fluctuation and its applications”. Przegląd Elektrotechniczny, no. 5, 2008, pp. 259-264. (in Polish)