PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Insulation resistance influence on high resistance Hamon transfer accuracy

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Accuracy of high resistance Hamon transfers, used for comparison of standard resistors with the ratios of 1:10 and 1:100, depends mainly on insulation leakage. Analysis of the influence of insulation resistance on the transfers accuracies and description of the method of minimizing the insulation leakage current effect by the usage of double insulation are the subject of this paper.
Rocznik
Strony
33--45
Opis fizyczny
Bibliogr. 17 poz., rys.
Twórcy
autor
autor
  • Wroclaw University of Technology, Faculty of Electrical Engineering, Institute of Electrical Engineering Fundamentals, Wybrzeże Wyspiańskiego 27, 50-370 Wrocław, Poland, michal.lisowski@pwr.wroc.pl
Bibliografia
  • [1] B. Jeckelmann, B. Jeanneret: “The quantum Hall effect as an electrical resistance standard”. Measurement Science and Technology, vol. 14 (2003), pp. 1229-1236.
  • [2] A. Hartland: “The quantum Hall effect and resistance standard”. Metrologia, vol. 29 (1992), pp. 175-190.
  • [3] E. Dudek: “Quantum Hall effect and its application in reproduction of the resistance unit”, Conference proceeding: Podstawowe Problemy Metrologii PPM’05, Ustroń 2005., pp. 409-416. (in Polish).
  • [4] W. Nawrocki, M. Wawrzyniak: “Quantum effects in electrical metrology”. Proc. Poznan University of Technology, Poznań 2003. (in Polish).
  • [5] M.J. Williams, P. Kleinschmidt: “A cryogenic current comparator bridge for resistance measurements at currents of up to 100A”, IEEE Transactions on Instrumentation and Measurement, vol. 48, no. 2, April 1999, pp. 375-378.
  • [6] R. F. Dziuba, R.E. Elmquist: “Improvements in resistance scaling at NIST using cryogenic current comparator”. IEEE Transaction on Instrumentation and Measurement, vol. 42 (1993), no. 2, pp. 126-130.
  • [7] J.M. Williams J.M., A. Hartland: “An automated cryogenic current comparator resistance ratio bridge”, IEEE Trans. Instrum. Meas. vol. 40 (1991), no. 2, pp.267-270.
  • [8] Measurement International: “Model 6000B Automated High Resistance Ratio Bridge”. Model information, http://www.mintl.com.
  • [9] Keithley: “Model 6517B Electrometer/high resistance meter”, www.keithley.com.
  • [10] Guildline: “Model6500AProgrammableDigitalTeraohmmeter”, http://www.bandp.co.kr/electronic/pdf/Guildline6500ADatasheet.pdf.
  • [11] J. Skurzak: “Methods of resistance standards comparison with high ratio of its resistance value”. Doctor of engineering dissertation, Institute of Electrical Metrology of Wroclaw University of Technology, Wrocław 1973. (in Polish).
  • [12] J. Dudziewicz, et al: “Etalons and precision measurements of electrical quantity”. Proc. WKiŁ, Warszawa 1982, pp. 156-170. (in Polish).
  • [13] R.E. Elmquist, D.G. Jarrett, G.R. Jones, E.K. Marlin, S.H. Shields, R.F. Dziuba: “NIST Measurement Service for DC Standard Resistors”. National Institute of Standards and Technology, Technical Note 1458, December 2003.
  • [14] D.G. Jarret: “Evaluation of guarded high-resistance Hamon Transfer Standards”. IEEE Trans. Instrum. Measure., vol. 48 (1999), no. 2, pp. 324-328.
  • [15] D.G. Jarret: “A 10 T per step Hamon transfer standard”. 2002 Conference on Precision Electromagnetic Measurements, Ottawa, Ontario, Canada, June 2002, Conf. Digest, pp. 54-55.
  • [16] M. Lisowski, K. Krawczyk: “The resistance unit transfer from the quantum Hall effect standard to high value resistance standards”, Pomiary Automatyka Kontrola, vol. 53 (2007), no. 9, pp. 88-91. (in Polish).
  • [17] M. Lisowski, K. Krawczyk: “Analysis of insulation resistance influence on high resistance Hamon transfer accuracy”. Electrical Review, vol. 85 (2009), no. 2, pp. 75-78.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSW1-0054-0003
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.