Wider reinforced masonry shear walls subjected to cyclic lateral loading

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
artially grouted wider reinforced masonry wall, built predominantly with the use of face shell bedded hollow concrete pcks, is adopted extensively in the cyclonic areas due to its economy. Its out-of-plane response to lateral pressure loading swell defined; however, its in-plane shear behaviour is less well understood, in particular it is unclear how the grouted reiniKrced cores affect the load paths within the wall. For the rational design of the walls, clarification is sought as to whether ! wall acts as a composite of unreinforced panels surrounded by the reinforced cores or simply as a continuum embedded Partially reinforcement at wider spacing. This paper reports four full scale walls tested under in-plane cyclic shear loading to vide some insight into the effect of the grout cores in altering the load paths within the wall. The global lateral load lateral deflection hysteretic curves as well as the local responses of some critical zones of the shear walls are presented. It is shown that the aspect ratio of the unreinforced masonry panels surrounded by the reinforced grouted cores within the shear walls have profound effect in ascertaining the behavior of the shear walls.
PL
Zbrojone ściany murowane, wykonane z drążonych bloczków betonowych częściowo wypełnionych zaprawą, są powszechnie głosowane na obszarach cyklonicznych ze względu na ekonomiczność tego rozwiązania. Dobrze znane jest zachowanie się takich murów obciążonych bocznym naporem. Znacznie słabiej rozpoznane jest ich zachowanie w przypadku naprężeń ścinających w płaszczyźnie elementu, a zwłaszcza niejasne jest jak zbrojone rdzenie z zaprawy oddziałują na ścieżki obciążenia wewnątrz muru. Ze względu na racjonalność projektowania takich ścian, przyjmuje się, że ściana pracuje jako kompozyt niezbrojonych paneli otoczonych przez zbrojone rdzenie lub po prostu jako ośrodek ciągły z osadzonym zbrojeniem w szerszych odstępach. W artykule przedstawiono cztery pełnowymiarowe ściany badane pod cyklicznym obciążeniem ścinającym w płaszczyźnie elementu aby dostarczyć danych na temat wpływu rdzeni z zaprawy na zmieniające się ścieżki obciążenia wewnątrz muru. Przedstawiono również globalne obciążenie boczne - krzywe histerezy bocznego ugięcia, jak również lokalne odpowiedzi niektórych stref krytycznych poddanych ścinaniu. Pokazano, że współczynnik kształtu niezbrojonych paneli murowych otoczonych zbrojonymi rdzeniami z zaprawy wewnątrz ścian poddanych ścinaniu ma znaczący wpływ na ustalenie zachowania się tych ścian.
Rocznik
Strony
39--46
Opis fizyczny
Bibliogr. 14 poz.
Twórcy
autor
  • Faculty of Built Environment and Engineering, Queensland University of Technology, Brisbane, Australia, m.dhanasekar@qut.edu.au
Bibliografia
  • [1] Shins P.B., Schuller M., Hoskere VS.; In-plane resistance of reinforced masonryshearwalls, Journal of Structural Engineering, Vol.116, No.3, 1990;p.619-640
  • [2] Australian standard for masonnry structures, 2001, Standard Australian International
  • [3] , M.S.J.C, Building code requirement for masonry structures,.2008: ACI 530/ASCE 5, IMS - 402, American Concrete Institute, Detroit, 2008
  • [4] CSA:S304.1-04, Design of masonry structures.Canadian Standards Association, 2004
  • [5] Dhanasekar M.; On the shear capacity equation formula in AS3700. in Proc Australasian Structural Engineering Conference, Gold Coast, 2001
  • [6] Dickie J.E., Lissel S.L.; Comparison of inplane masonry shear models, in 11t h Canadian Masonry Symposium, Toronto, Ontario, 2009
  • [7] Minaie E., Mota, M., Moon L., Hamid A.; In-Plane Behavior of Partially Grouted Reinforced Concrete Masonry Shear Walls, Journal of Structural Engineering, Vol.136, No.9, 2010; p.1089-1097
  • [8] Dhanasekar M., Shrive N.G, PageA.W.; Wide spaced reinforced masonry shearwalls, Computer Analysis and Design of Masonry Structures, John Bull (Ed), Saxe-Coburg Publishers, UK, ISBN 978-1-874672-44-9, 2011
  • [9] Haider W.; In-plane response of wide spaced reinforced masonry shear wall, Central Queensland University, Australia, 2007
  • [10] Dhanasekar M., Haider W.; Effect of spacing of reinforcement on the behaviour of partially grouted masonry shear walls, Advances in Structural Engineering, 2010
  • [11] Mojsilovic N., Simundic G. and PageA.W.; Masonry wallettes with damp-proof course membrane subjected to cyclic shear: An experimental study Construction and Building Materials, Vol.24, 2010; p.2135-2144
  • [12] Muguruma H, Nishiyama M., Watanabe E, Tnaka; Ductile behaviour of high strength concrete columns confined by high strength transverse reinforcement, ACI Special Publication: Evaluation and Rehabilitation of concrete structures and innovation in design, 1991; p.128-54 (88-AB)
  • [13] Saatcioglu M.; Modelling hysteretic force deformation relationship for reinforced concrete elements, ACI Journal, SP 125 (5), 1991; p.153-198
  • [14] Tena-ColungaA., Juarez-Angeles A., Salinas-Vallejo VH.; Cyclic behavior of combined and confined masonry walls, Engineering Structures, Vol.31, No.l, 2009; p.240-259
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSL9-0064-0004
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.