Many advantages of displacement piles result in their very common use of present. In case of displacement pile, of particular importance are the phenomena occurring in direct vicinity of the pile shaft, where partial or total pushing the soil out aside is observed. Changes of vertical and horizontal stresses, pore water pressure generation, changes in soil structure, its moisture content and density taking place during installation of displacement piles create almost new soil conditions at the contact of pile shaft and subsoil. The paper presents the results of CPT tests carried out in the subsoil around CFA piles particularly in layered soils (non-cohesive/cohesive ones). Special attention is paid to a selection of proper parameters of drilling machine and concreting technology to form the pile. It is planned to continue the investigations based on theoretical description in the frame of soil mechanics.
PL
Stosowanie wierconych pali przemieszczeniowych jest obecnie bardzo częste. Wiele zalet tych pali będzie predysponowało je do powszechnego stosowania. Szczególne znaczenie mają zjawiska zachodzące w bezpośrednim sąsiedztwie pobocznicy pala gdy mamy do czynienia z częściowym lub całkowitym rozpychaniem gruntu na boki. Zmiany stanu naprężenia pionowego, poziomego, generacja ciśnienia wody w porach gruntu, zmiana struktury gruntu, wilgotności i zagęszczenia stwarza zupełnie nowe warunki oddziaływania w strefie pobocznica pala - zmienne podłoże gruntowe. W artykule przedstawiono wyniki badań sondą statyczną CPT w sąsiedztwie pali CFA, ze szczególnym uwzględnieniem gruntów uwarstwionych: grunty spoiste/grunty niespoiste. Zwrócono uwagę na dobór parametrów maszyny i technologii betonowania w zależności od rodzaju gruntu. Dalsze badania będą zmierzały do wyjaśnienia zmian w podłożu gruntowym w odniesieniu do zasad opisujących zmiany w ujęciu teorii mechaniki gruntów.
Rocznik
Strony
43--50
Opis fizyczny
Bibliogr. 8 poz.
Twórcy
autor
autor
  • Faculty of Civil and Environmental Engineering, Gdańsk University of Technology, ul. G. Narutowicza 11,12, 80-952 Gdańsk; Poland, kgwiz@pg.gda.pl
Bibliografia
  • [1] Bottiau M.J., Recent Evolutions in Deep Foundation Technologies, Piling and Deep Foundations, 10th International Conference, Amsterdam, 2006; p. 46-83.
  • [2] Bottiau M.J., Meyus IA., Russo G., Van Impe P.O.; Introducing the Omega Pile - Load Testing at Feluy Test Site, DFBAP, Rotterdam, Balkema, 1998; p. 187-199.
  • [3] Bustamante M., Auger and Bored Pile Construction Monitoring and Testing, DFBAP, Rotterdam, Millpress, 2003; p. 27-41.
  • [4] EFFC, The European Federation of Foundation Contractors, Forum Court, Backenham, United Kingdom, No 31, 2006; p. 15-17.
  • [5] Gwizdała K., Ekologiczne aspekty projektowania fundamentów palowych (Ecological aspects of pile foundations designing), 2007. Problems of civil engineering on ecologically valuable areas. Polska Akademia Nauk. Komitet Inżynierii Lądowej i Wodnej. Wydawnictwo Politechniki Białostockiej, 2007, p. 297-308 (in Polish).
  • [6] Hannik G., Reduction of the cone resistance caused by the installation of CFA piles, 16th International Conference of Soil Mechanics and Geotechnical Engineering, Osaka, 2005.
  • [7] Van Impe P.O., Van Impe W.F., Verstraeten K., Experiences with CFA pile type under an existing building, DFBAP, Rotterdam, Balkema, 1998; p. 273-279.
  • [8] Van Impe W F., Deep Foundations on Bored and Auger Piles, BAP IV, Ghent, 2003; p. 3-9.