Development trends of mucous-borne dentures in the aspect of elastomers applications

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Purpose: The aim of this study is to foreseen the influence of elastomers on the development of mucous-borne dentures in the aspect of bio-compatible use of prosthetic foundation tissue load bearing capacity. Design/methodology/approach: Multi-criteria comparative analysis based on the dendrological matrix of attractiveness and potential was used for the studies of denture solution and materials. There were differentiated seven groups of conventional dentures without an implantological stabilisation - the so-called hard dentures (CD) and those with a soft relining (CD-P), stabilized on one implant (SID) or on two implants (TID), that were differentiated as far as the denture attachment to implant was concerned. The first group was marked as "hard" (K) due to the used materials and inconsiderable lateral compliance. The elastomeric attachments (S) constituted the second group of attachments. Findings: In case of conventional dentures a significant influence of the relining on attractiveness was observed. In case of dentures retained on elastomeric attachments - they decided not only on the attractiveness, but they have also significantly increased dentures' potential. Research limitations/implications: Throughout the studies the variation of denture bearing structure materials were not taken into account, based on the assumption that acrylates are the most commonly used. Practical implications: The similar level of attractiveness of dentures retained on implants significantly varying as far as their construction is concerned shows that the focus should be mainly put on material design of elastomers' wearing characteristics. Originality/value: Multi-criteria heuristic analysis proved to be an effective tool for examination of dentures in the aspect evaluation of dentures material and cosntruction that show perspectives of the broadest use due to exploitation of the tissue bearing capability.
Rocznik
Strony
5--13
Opis fizyczny
Bibliogr. 61 poz.
Twórcy
autor
  • Faculty of Mechanical Engineering, Silesian University of Technology, ul. Konarskiego 18a, 44-100 Gliwice, Poland, jaroslaw.zmudzki@polsl.pl
Bibliografia
  • [1] F. Muller, M. Naharro, G.E. Carlsson, What are the prevalence and incidence of tooth loss in the adult and elderly population in Europe?, Clinical Oral Implants Research 18/3 (2007) 2-14.
  • [2] Z. Raszewski, New look on the dental acrylates, Elamed, Katowice, 2009 (in Polish).
  • [3] Y.D. Zhang, Z.F. Zhao, P.J. Lu, Y. Wang , R.J. Song, J.L. Lu, Robotic System Approach for Complete Denture Manufacturing, Transactions on Mechatronics 7/3 (2002) 392-396.
  • [4] M. Busch, B. Kordass, Concept and development of a computerized positioning of prosthetic teeth for complete dentures, International Journal of Computerized Dentistry 9/2 (2006) 113-120.
  • [5] C. Xiaojun, L. Rubo, L. Eryi, W. Chengtao, A computerized simulation system of mandibular movement on Hanau articulator, Engineering in Medicine and Biology Society 5 (2005) 5136-3519.
  • [6] H. Sondermann, A. Sobolewska, Studies of dysfunction and removal of dental prosthesis, Dental Forum XXXVIII/1 (2010) 19-26.
  • [7] F. Kawano, K. Nagao, S. Inoue, N. Matsumoto, Influence of the buccolingual position of artificial posterior teeth on the pressure distribution on the supporting tissue under a complete denture, Journal of Oral Rehabilitation 23/7 (1996) 456-463.
  • [8] The McGill consensus statement on overdenture, Quintessence International 34/1 (2003) 78-79.
  • [9] M. Lujan-Climent, J. Martinez-Gomis, S. Palau, R. Ayuso-Montero, J. Salsench, M. Peraire, Influence of static and dynamic occlusal characteristics and muscle force on masticatory performance in dentate adults, European Journal of Oral Sciences 116/3 (2008) 229-236.
  • [10] K. Obłój, A success strategy of a firm, PWE, Warsaw, 1994 (in Polish).
  • [11] A.D. Dobrzańska-Danikiewicz, Foresight methods for technology validation, roadmapping and development in the surface engineering area, Archives of Materials Science Engineering 44/2 (2010) 69-86.
  • [12] A.D. Dobrzańska-Danikiewicz, Computer integrated development prediction methodology in materials surface engineering, Open Access Library 1/7 (2012) 1-289.
  • [13] A.D. Dobrzańska-Danikiewicz, Foresight of material surface engineering as a tool building a knowledge-based economy, Materials Science Forum 706/709 (2012) 2511-2516.
  • [14] A.D. Dobrzańska-Danikiewicz, E-foresight of materials surface engineering, Archives of Materials Science Engineering 44/1 (2010) 43-50.
  • [15] A. Dobrzańska-Danikiewicz, The methodological fundaments of development state analysis of surface engineering technologies, Journal of Achievements in Materials and Manufacturing Engineering 40/2 (2010) 203-210.
  • [16] I. Hayakawa, S, Hirano, Y. Takahashi, E.S. Keh, Changes in the masticatory function of complete denture wearers after relining the mandibular denture with a soft denture liner, The International Journal of Prosthodontics 13/3 (2000) 227-231.
  • [17] S. Kimoto, K. Kimoto, A. Gunji, Y. Kawai, H. Murakami, K. Tanaka, K. Syu, H. Aoki, M. Tani, M. Toyoda, K. Kobayashi, Clinical effects of acrylic resilient denture liners applied to mandibular complete dentures on the alveolar ridge, Journal of Oral Rehabilitation 34/11 (2007) 862-869.
  • [18] H. Murata, N. Taguchi, T. Hamada, M. Kawamura, J.F. McCabe, Dynamic viscoelasticity of soft liners and masticatory function, Journal of Dental Research 81 (2002) 123-128.
  • [19] M. Shinomiya, In-vivo and In-vitro Studies for Analysis of Mastication in Complete Denture Wearers with Resilient Denture Liners, International Journal of Oral-Medical Science 5/2 (2006) 107-116.
  • [20] D.R. Burns, J.W. Unger, R.K. Elswick, D.A. Beck Jr, Prospective clinical evaluation of mandibular implant overdentures, Part I - retention, stability, and tissue response, Journal of Prosthetic Dentistry 73 (1995) 354-363.
  • [21] M.I. MacEntee, J.N. Walton, N. Glick, A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures, Three-year results, Journal of Prosthetic Dentistry 93 (2005) 28-37.
  • [22] G. Heydecke, J.R. Penrod, Y. Takanashi, J.P. Lund, J.S. Feine, J.M. Thomason, Cost-effectiveness of mandi-bular two-implant overdentures and conventional dentures in the edentulous elderly, Journal of Dental Research 84/9 (2005) 794-799.
  • [23] K.K. Kapur, N.R. Garrett, M.O. Hamada, E.D. Roumanas, E. Freymiller, T. Han, R.M. Diener, S. Levin, R. Ida, A randomized clinical trial comparing the efficacy of mandibular implant-supported overdentures and conventional dentures in diabetic patients, Part I, Methodology and clinical outcomes, Journal of Prosthetic Dentistry 79/5 (1998) 555-569.
  • [24] G. Cordioli, Z. Majzoub, S. Castagna, Mandibular overdentures anchored to single implants: A five-year prospective study, Journal of Prosthetic Dentistry 78 (1997) 159-165.
  • [25] A. Haruta, Y. Matsushita, Y. Tsukiyama, Y. Sawae, N. Sakai, K. Koyano, Effects of mucosal thickness on the stress distribution and denture stability of mandibular implant-supported overdentures with unsplinted attachments in vitro, Journal of Dental Biomechanics (2011) 1-7.
  • [26] G. Menicucci, M. Lorenzetti, P. Pera, G. Preti, Mandibular implant-retained overdenture: finite element analysis of two anchorage systems, International Journal of Oral and Maxillofacial Implants13/3 (1998) 369-376.
  • [27] J. Duyck, H. van Oosterwyck, J. Vander Sloten, M. de Cooman, R. Puers, I. Naert, In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system, Clinical Oral Investigations 3/4 (1999) 201-207.
  • [28] J.A. Porter Jr, V.C. Petropoulos, J.B. Brunski, Comparison of load distribution for implant overdenture attachments,. The International Journal of Oral and Maxillofacial Implants 17/5 (2002) 651-662.
  • [29] M. Daas, G. Dubois, A.S. Bonnet, P. Lipinski, C. Rignon-Bret, A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations, Medical Engineering and Physics 30/2 (2008) 218-225.
  • [30] Y. Maeda, M. Horisaka, K. Yagi, Biomechanical rationale for a single implant-retained mandibular overdenture: an in vitro study, Clinical Oral Implants Research 19 (2008) 271-275.
  • [31] T. Ichikawa, M. Horiuchi, R. Wigianto, N. Matsumoto, In vitro study of mandibular implant-retained overdentures: the influence of stud attachments on load transfer to the implant and soft tissue, The International Journal of Prosthodontics 9/4 (1996) 394-399.
  • [32] M Tokuhisa, Y Matsushita, K Koyano, In vitro study of a mandibular implant overdenture retained with ball, magnet or bar attachments, Comparison of load transfer and denture stability, The International Journal of Prosthodontics 16/2 (2003) 128-134.
  • [33] R. Kenney, M.W. Richards, Photoelastic stress patterns produced by implant-retained overdentures, Journal of Prosthetic Dentistry 80 (1998) 559-564.
  • [34] J. Żmudzki, Can typical overdentures attachments prevent from bone overloading around mini-implants?, Journal of Achievements in Materials and Manufacturing Engineering 43/2 (2010) 542-55.
  • [35] J. Żmudzki, G. Chladek, J. Kasperski, Silicone attachment for avoidance of bone tissue overloading in single implant-retained denture, Archives of Materials Science and Engineering 51/2 (2011) 107-115.
  • [36] J. Żmudzki, W. Chladek, Identification of biomechanics related to single implant-retained tissue-supported dentures, Prosthodontics LX/1 (2010) 22-27 (in Polish).
  • [37] W. Chladek, G. Chladek, T. Cząstkiewicz, J. Kasperski, J. Żmudzki, Frictional attachment to stabilization overdentures, Polish Patent No 207 272, 2004 (in Polish).
  • [38] W. Chladek, G. Chladek, J. Żmudzki, The attachment with socket on implantological pillar for overdentures stabilization, Polish Patent No 375 662, 2005 (in Polish).
  • [39] W. Chladek, G. Chladek, T. Lipski, J. Margielewicz, J. Żmudzki, Biomechanical problems related to design ofimplantological overdenture stabilization system, Monographs, No. 152, Silesian University of Technology Press, Gliwice, 2008 (in Polish).
  • [40] J. Żmudzki, W. Chladek, Assesment of occlusal loadings on supporting areas depending on overdenture implants attaching mechanisms, Protetyka Stomatologiczna LIX/3 (2009) 206 (in Polish).
  • [41] M. Wrzuś-Wieliński, A trial to use silicones for direct attachments of overdentures. Non-published PhD Thesis, Medical University of Łódź, Łódź, 2009 (in Polish).
  • [42] S. Kimoto, K. Kimoto, A. Gunji, Y. Kawai, H. Murakami, K. Tanaka, K. Syu, H. Aoki, M. Tani, M. Toyoda, K. Kobayashi, Clinical effects of acrylic resilient denture liners applied to mandibular complete dentures on the alveolar ridge, Journal of Oral Rehabilitation 34/11 (2007) 862-9.
  • [43] H. Murata, N. Taguchi, T. Hamada, M. Kawamura, J.F. McCabe, Dynamic viscoelasticity of soft liners and masticatory function, Journal of Dental Research 81 (2002) 123-128.
  • [44] I. Hayakawa, S. Hirano, Y. Takahashi, E.S. Keh, Changes in the masticatory function of complete denture wearers after relining the mandibular denture with a soft denture liner, The International Journal of Prosthodontics 13/3 (2000) 227-231.
  • [45] M Shinomiya, In-vivo and In-vitro Studies for Analysis of Mastication in Complete Denture Wearers with Resilient Denture Liners, International Journal of Oral-Medical Science 5/2 (2006) 107-116.
  • [46] S. Kimoto, K. So, S. Yamamoto, Y. Ohno, M. Shinomiya, K. Ogura, K. Kobayashi, Randomized controlled clinical trial for verifying the effect of silicone-based resilient denture liner on the masticatory function of complete denture wearers, The International Journal of Prosthodontics 19/6 (2006) 593-600.
  • [47] H.J. Wilson, H.R. Tomlin, J. Osborne, The assessment of temporary soft materials used in prosthetic dentistry, British Dental Journal 126 (1969) 303-306.
  • [48] H. Murata, N. Taguchi, T. Hamada, J.F. McCabe, Dynamic viscoelastic properties and the age changes of long-term soft denture liners, Biomaterials 21 (2000) 1421-1427.
  • [49] N. Taguchi, H. Murata, T. Hamada, G. Hong, Effect of viscoelastic properties of resilient denture liners on pressures under dentures, Journal of Oral Rehabilitation 28/11 (2001) 1003-1008.
  • [50] F. Kawano, A. Koran 3rd, K. Asaoka, N. Matsumoto, Effect of soft denture liner on stress distribution in supporting structures under a denture, The International Journal of Prosthodontics 6/1 (1993)43-49.
  • [51] J. Żmudzki, W. Chladek, Effectiveness of soft relining in eliminating injuries of denture foundation assessed by means of FEM model analysis, Prosthodontics LIX/6 (2009) 394-400 (in Polish).
  • [52] J. Kasperski, J. Żmudzki, G. Chladek, Denture foundation tissues loading criteria in evaluation of dentures wearing characteristics, Journal of Achievements in Materials and Manufacturing Engineering 43/1 (2010) 324-332.
  • [53] S. Żółkiewski, Testing composite materials connected in bolt joints, Journal of Vibroengineering 13/4 (2011) 817-822.
  • [54] F. Kawano, E.R. Dootz, A. Koran 3rd, et al., Comparison of bond strength of six soft denture liners to denture base resin, Journal of Prosthetic Dentistry 68 (1992) 368-371.
  • [55] EN ISO 10139-2:2009 Dentistry - Soft lining materials for removable dentures - Part 2: Materials for long-term use.
  • [56] A.K. Aydin, H. Terzioglu, A.E. Akinay, K. Ulubayram, N. Hasirci, Bond strength and failure analysis of lining materials to denture resin, Dental Materials 15/3 (1999) 211-218.
  • [57] G. Chladek, A. Mertas, I. Barszczewska-Rybarek, T. Nalewajek, J. Żmudzki, W. Król, J. Lukaszczyk, Antifungal activity of denture soft lining material modified by silver nanoparticles- a pilot study, International Journal of Mole-cular Sciences 12/7 (2011) 4735-4744
  • [58] G. Chladek, Nanocomposite materials improved by nanosilver for the denture soft linings for long-term use, Open Access Library 3/9 (2012) 1-144 (in Polish).
  • [59] I.E. Naert, M. Hooghe, M. Quirynen, D. van Steenberghe, The reliability of implant-retained hinging overdentures for the fully edentulous mandible. An up to 9-year longitudinal study, Clinical Oral Investigations 1 (1997) 119-124.
  • [60] A.C.L. den Dunnen, A.P. Slagter, C. de Baat, C. Kalk, Professional hygiene care, adjustments and complications of mandibular implant-retained overdentures, A three-year retrospective study, Journal of Prosthetic Dentistry 78 (1997) 387-390.
  • [61] A.G. Payne, Y.F. Solomons, Mandibular implant-supported overdentures: a prospective evaluation of the burden of prosthodontic maintenance with 3 different attachment systems, The International Journal of Prosthodontics 13 (2000) 246-263.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSL8-0050-0001
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.