Fluid therapy is essential part of treatment after cardiac surgery. Optimal objective monitoring of its efficacy in hemodynamic stabilization of patients is the subject of ongoing discussion. There are several methods of evaluation of fluid responsiveness and cardiac preload in clinical practice. Among them central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) should be mentioned. On the other hand, systolic pressure variation (SPV) in mechanically ventilated patients is one of the easiest methods of measurement of fluid responsiveness. The purpose of the study was to develop SPV measurement methodology and to apply it as a marker of fluid responsiveness and cardiac preload in patients who underwent coronary artery bypass grafting (CABG) with the use of cardiopulmonary bypass (CPB).
Rocznik
Tom
Strony
351--356
Opis fizyczny
Bibliogr. 13 poz.
Twórcy
autor
autor
  • Department of Clinical Engineering and New Medical Technology, The John Paul II Hospital in Krakow, Poland
Bibliografia
  • [1] Godje O., Peyerl M., Seebauer T. et al.: Central venous pressure, pulmonary capillary wedge pressure and intrathoracic blood volumes as preload indicators in cardiac surgery patients. Eur J Cardiothorac Surg 1998, 13, pp. 533-539, discussion pp. 539-540.
  • [2] Hansen R. M., Viquerat C. E., Matthay M. A. et al.: Poor correlation between pulmonary arterial wedge pressure and left ventricular end - diastolic volume after coronary artery bypass graft surgery. Anesthesiology 1986, 64, pp. 764-770.
  • [3] Perel A., Pizov R., Cotev S.: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987, 67, pp. 498-502.
  • [4] Tavemier B., Makhotine 0., Lebuffe G., Dupont J., Scherpereel P.: Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998, 89, pp. 1313-1321.
  • [5] Teboul J. L., Monnet X., Richard C: Arterial pulse pressure variation during positive pressure ventilation and passive leg raising. In Functional Hemodynamic Monitoring. Edited by Pinsky M.R., Payen D. Springer-Verlag, Berlin 2004, pp. 331-343.
  • [6] Preisman S., Pfeiffer U., Lieberman N., Perel A.: New monitors of intravascular volume: A comparison of arterial pressure waveform analysis and the intrathoracic blood volume. Int Care Med 1997,23, pp. 651-657.
  • [7] Schwid H. A., Rooke G. A.: Systolic blood pressure at end-expiration measured by the automated systolic pressure variation monitor is equivalent to systolic blood pressure during apnea. J ClinMonit 2000, 16, pp. 115-120.
  • [8] Szkodny P., Wąsowicz M., Ziętkiewicz M. et al: Analiza wahań krzywej ciśnienia tętniczego jako wykładnika wypełnienia łożyska naczyniowego u chorych operowanych z użyciem krążenia pozaustrojowego (CPB). Anestezjologia Intensywna Terapia 2004, 4, pp. 255-259.
  • [9] Bjorck A., Dalquist G.: Metody numeryczne. PWN, Warszawa 1987.
  • [10] Smoluk A., Podstawy teorii aproksymacji i s-funkcje. PWN, Warszawa 1974.
  • [11]Engeln-Müllges G., Uhlig F.: Numerical Algorithms with C. Springer-Verlag, Berlin 1996.
  • [12] Soncini M., Manfredi G., Redaelli A. et al.: A computerized method to measure systolic pressure variation (SPV) in mechanically ventilated patients. J Clin Monit 2002, 17, pp. 141-146.
  • [13] Fujita Y., Sari A., Yamamoto T.: On-line monitoring of systolic pressure variation. Anesth Analg 2003, 96, pp. 1529-1530.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSL8-0035-0037
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.