Pollutant concentrations from a heat station fuelled with a wood pellet and coffee husk pellet mixture

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Stężenia zanieczyszczeń z kotłowni zasilanej mieszaniną peletów drzewnych i peletów z łusek kawy
Języki publikacji
EN
Abstrakty
EN
CO, CxHy, NO, NOx and dust concentrations from a heat station with a boiler of 15 kW nominal heat output supplied with a wood pellet and coffee husk pellet mixture were researched . In the entrained flow furnace designed for firing wood pellet burning, melting and sintering ash phenomenon was not be successfully avoided. In comparison to wood pellet combustion, the observed boiler heat efficiency was lower. CO concentration was relatively high but did not exceed the permitted value. The impact of temperature in the combustion chamber and oxygen concentration on pollutant concentrations was determined. Pollutant emission indicators were estimated.
PL
W kotłowni grzewczej badano stężenia CO, CxHy, NO, NOx i pyłu z kotła o mocy nominalnej 15 kW, zasilanego mieszaniną peletów drzewnych i peletów z łusek kawy. W palenisku typu narzutowego dostosowanego do peletów drzewnych, mimo obniżenia temperatury, nie udało się uniknąć całkowicie zjawiska mięknienia i zlepiania się popiołu. Uzyskano niższą niż dla peletów drzewnych sprawność cieplną kotła oraz wyższe stężenie tlenku węgla, lecz poniżej dopuszczalnej wartości. Określono wpływ temperatury w komorze spalania i stężenia tlenu na stężenia zanieczyszczeń. Oszacowano wskaźniki emisji.
Rocznik
Strony
51--58
Opis fizyczny
Bibliogr. 10 poz.
Twórcy
autor
  • Poznan University of Technology , Institute of Environmental Engineering, ul. Piotrowo 3a, 60-965 Poznań, tel.: 61-665-35-24, fax: 61-665-24-39, marekjuszczak8@wp.pl
Bibliografia
  • 1. Knaus H., Richter S., Unterberger S., Snell U., Maier H., Hein K.R.G., On the application of different turbulence models for the computation of flow and combustion process in small scale wood heaters, Experimental Thermal and Fluid Science 21 (2000), p. 99-108,
  • 2. Werther J., Saenger M., Hartge E. U., Ogada T., Siagi Z., Combustion of agricultural residues, Progress in Energy and Combustion Science 26 (2006), p.1-27,
  • 3. Rybak W., Combustion and co-combustion of solid biofuels, Wroclaw University of Technology, Wroclaw, 2006 (in polish),
  • 4. Ohman M., Boman C., Hedman H., Nordin A., Bostrom D., Slagging tendencies of wood pellet ash during combustion in residential pellet furnace, Biomass and Bioenergy, 27 (2004), p.585-596,
  • 5. EN 12048, Solid fertilizers and liming materials - Determination of moisture content - Gravimetric method by drying at (105 ±2°C), December 1999,
  • 6. PN-81/G-04513 Solid fuels. Higher heating value measurement and lower heating value calculation (in polish),
  • 7. Kruczek S., Boilers. Constructions and calculations, Wroclaw University of Technology, Wroclaw 2001 (in polish),
  • 8. PN-EN 3003-5, Heating boilers, part 5. Heating boilers for solid fuels, hand and automatically stocked nominal heat output of up to 300 kW. Terminology, requirements and marking, 2004,
  • 9. Juszczak M., Investigations of heat station with the boiler utilizing pellet furnace, Archiwum Gospodarki Odpadami i Ochrony Środowiska, vol.8 (2008), p.63-68,
  • 10. Błaszczak J. Investigations of pollutant concentrations from the boilers with wood furnaces during changes of boiler water stream rate, master thesis, Poznan University of Technology, 2009 (in polish).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BSL4-0015-0006
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.